Defective area
Main charger output
Developer bias output
Transfer belt
Note:
1. Toner density correcting method
Change the setting value 'Toner density life correction setting (08-2816)' (6 is the default setting.)
0: Approx. 0.75% lower than the current value
1: Approx. 0.50% lower than the current value
2: Approx. 0.25% lower than the current value
3: The current value (Default setting)
4: Approx. 0.15% higher than the current value
5: Approx. 0.25% higher than the current value
6: Approx. 0.50% higher than the current value
7: Approx. 0.75% higher than the current value
<Caution for correction>
When increasing or decreasing the toner density too much, the image may become poor or the
life of developer material, cleaner, photoconductive drum and fuser unit, etc. may shorten.
Therefore it is not recommended to correct (to shift) the toner density basically. If it is shifted,
make sure that the image may be improper in a few minutes after shifting.
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
Step
Check items
14
Is the setting value proper?
Is the main charger output normal?
15
Is the setting value proper?
Is the developer bias output normal?
16
Is there any foreign object or fiber,
etc. on the belt surface?
8 - 253
Prescription
Replace the high-voltage transformer
with a new one and print out a test
chart.
If any abnormal image appears,
check the harness connection
between the LGC board and the
high-voltage transformer, power
supply and stain on the main charger
wire.
Replace the high-voltage transformer
with a new one and print out a test
chart.
If any abnormal image appears,
check the harness connection
between the LGC board and the
high-voltage transformer, power
supply and stain on the main charger
wire.
Remove it.
e-STUDIO556/656/756/856/557/657/757/857
ERROR CODE AND TROUBLESHOOTING
8