[Procedure 2]
Is the safety zone switch (MS3) working normally?
NO 
YES
Is the safety zone switch (MS3) correctly pressed?
NO 
YES
Is the swing guide closed detection switch-2 (MS6) working normally?
NO 
YES
Is the swing guide closed detection switch-2 (MS6) correctly pressed?
NO 
YES
Replace the finisher controller PC board.
[Procedure 3]
Is the swing motor clock sensor (PI20) working normally?
NO 
YES
MJ-1027/1028:
Does the voltage between J11-6 and -7 on the finisher controller PC board become 24V
when the swing motor starts rotating?
MJ-1029:
Does the voltage between J9-6 and -7 on the finisher controller PC board become 24V
when the swing motor starts rotating?
NO 
YES
Is the wiring between the swing motor and finisher controller PC board correct?
YES  Correct the wiring.
NO
Replace the swing motor.
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
Replace the switch.
Fix the mechanism.
Replace the switch.
Fix the mechanism.
Replace the sensor.
Replace the finisher controller PC board.