4.9.3
New toner supply motor (M5)
(1)
Remove 3 screws to take off the top cover.
(2)
Disconnect 1 connector, remove 2 screws,
and then take off the new toner supply motor.
Note:
Pay attention to the size (length) of the
screws. If incorrect ones are used, the motor
could be damaged.
4.9.4
Toner cartridge empty sensor (S10)
(1)
Remove 2 screws, and then take off the
toner cartridge empty sensor with the
harness.
(2)
Disconnect 1 connector from the toner
cartridge empty sensor.
Note:
Be careful not to damage the sensor when
connecting and disconnecting the connector.
4.9.5
New toner transport motor (M6)
(1)
Remove 3 screws to take off the top cover.