Download Print this page

Toshiba e-STUDIO556 Service Manual page 185

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO556:

Advertisement

Note:
Rotate the drive pulley to move the carriage.
(3)
Disconnect 1 connector.
(4)
Remove 3 screws, and take off the Exposure
lamp cooling fan-1.
Note:
When installing the fan, do not tighten the
screw too much.
4.3.11
Exposure lamp cooling fan-2 (M37)
(1)
Take off the original glass.
( P.4-11 "4.3.1 Original glass")
(2)
Move the carriage-1 to the right side.
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
Fig. 4-57
Exposure lamp cooling fan-1
Fig. 4-58
Fig. 4-59
e-STUDIO556/656/756/856/557/657/757/857
4 - 21
Drive pulley
DISASSEMBLY AND REPLACEMENT
4

Advertisement

loading