Download Print this page

Toshiba e-STUDIO556 Service Manual page 699

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO556:

Advertisement

[F109_1] Key consistency error (SRAM encryption AES key data damage)
Classification
Other service call
Check item
Setting
[F109_2] Key consistency error (Signature Check public key damage)
Classification
Other service call
Check item
Setting
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved
Key consistency error - AES key data used for SRAM encryption are
damaged.
Reboot the equipment.
If it cannot be recovered, reinstall the software in the following procedure.
Install the OS data.
 P.11-12 "11.2.3 Master data / System ROM / Laser ROM / PFC
ROM / Engine ROM / Scanner ROM / RADF ROM"
Reinstall the master data and application program.
Key consistency error - Public key data used for Integrity Check are
damaged.
Reboot the equipment.
If it cannot be recovered, reinstall the software in the following procedure.
Install the OS data.
 P.11-12 "11.2.3 Master data / System ROM / Laser ROM / PFC
ROM / Engine ROM / Scanner ROM / RADF ROM"
Reinstall the master data and application program.
8 - 147
Error item
Measures
Error item
Measures
e-STUDIO556/656/756/856/557/657/757/857
ERROR CODE AND TROUBLESHOOTING
8

Advertisement