The following icons may be displayed during a non-recoverable
alarm that does NOT require the instrument to be turned OFF,
but forces the end of a procedure:
Icon
Check separation chamber and centrifuge compartment.
When associated with a non-recoverable alarm, the system
has detected a leak in the centrifuge compartment.
Remove the kit and start a new procedure.
Check plasma line from centrifuge for redness. When
associated with a non-recoverable alarm, the system has
determined redness in the plasma line coming from the
centrifuge has been occurring for an extended period of
time.
In these instances, there are a couple of different alarm screens
that may be displayed. Examples of these are provided in the
following screens, along with explanations.
ANUAL
Meaning
07-19-01-518 – January 2009