Delta EtherCAT Programming Manual page 454

Table of Contents

Advertisement

EtherCAT Programming Guide
Code in DEC
Name of error
code
Description
Troubleshooting
Code in DEC
Name of error
code
Description
Troubleshooting
Code in DEC
Name of error
code
Description
Troubleshooting
Code in DEC
Name of error
code
Description
Troubleshooting
Code in DEC
Name of error
code
Description
Troubleshooting
Code in DEC
Name of error
code
March, 2017
18
ERR_ECAT_ENVIRONMENT_RECORD_DISABLE
The function of the Autoconfig file is not working due to the system
configuration error.
N/A
19
ERR_ECAT_ENVIRONMENT_RECORD_NO_MATCH
The hardware connection configuration saved by Autoconfig file does not
match the one for Fieldbus.
Communication for the hardware cannot be created. Please check if the
connection is normal.
20
ERR_ECAT_ENVIRONMENT_RECORD_FILE_OPEN
Fail to open the Autoconfig file.
Please check if the Autoconfig file is saved in the given directory.
21
ERR_ECAT_ENVIRONMENT_RECORD_NOT_CREATE
The Autoconfig file for saving the hardware connection configuration has not
been created.
Please execute the initialization procedure correctly.
23
ERR_ECAT_DEVICE_OPEN
The setting for initializing EtherCAT Master is in error.
An error has occurred when initializing EtherCAT Master. Please check if the
hardware connection is normal.
24
ERR_ECAT_NO_DEVICE
Code in HEX
0x12
Code in HEX
0x13
Code in HEX
0x14
Code in HEX
0x15
Code in HEX
0x17
Code in HEX
0x18
Error Code Description
34
34-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents