High Speed Pulse Compare Function
27.17 _ECAT_Compare_Get_Channel1_Position _Table_Count
Syntax
27
U16 PASCAL _ECAT_Compare_Get_Channel1_Position_Table_Count (U16 CardNo,
U32* cnt)
Purpose
Acquire the current trigger counts of channel 1.
Parameter
Name
CardNo
Cnt
Example
U16 CardNo = 0;
U32 cnt;
U16 status = _ECAT_Compare_Get_Channel1_Position_Table_Count (CardNo,& cnt);
27-24
Data type
Property
U16
Number
U32*
Numeric value
Description
Card No.
Acquire the trigger counts of channel 1.
EtherCAT Programming Guide