Ecat_Compare_Channel0_Position; Ecat_Compare_Set_Channel_Trigger_Time - Delta EtherCAT Programming Manual

Table of Contents

Advertisement

High Speed Pulse Compare Function

27.9 _ECAT_Compare_Channel0_Position

Syntax
27
U16 PASCAL _ECAT_Compare_Channel0_Position(U16 CardNo, I32 Start, U16 Dir, U16
Interval, U32 TriggerCount);
Purpose
Set the parameters for triggering the signal at a fixed pulse interval of channel 0.
Note:
1.
For the trigger retaining time, please refer to description of API

"_ECAT_Compare_Set_Channel_Trigger_Time".

2.
Output signal of channel 0 is triggered via PIN11 and PIN12 of CN2 and CN9 connector on motion card
PCI-L221-B1. These two sets of points will both be triggered when pulses are matched
Parameter
Name
CardNo
Start
Dir
Interval
Trigger_cnt
Example
U16 CardNo = 0;
I32 start = 100000;
U16 dir = 0;
U16 Interval = 10; //10 pulse
U32 trigger_cnt = 50000;
U16 status=_ECAT_Compare_Channel0_Position(CardNo, start, dir, interval, trigger_cnt);
/* The motion card starts comparing pulses from position 100000 and channel 0 will be triggered
once every 10 pulses with total trigger count 50000. */
/* That is, when it is at position 100010, 100020, 100030, ..., 600000 (pulse), channel 0 will be
triggered once.*/
Description
The motion card starts comparing pulses from the start position and trigger a differential signal
based on the set pulse interval (every time a given pulse number is reached). Meanwhile, the
motion card carries on comparing the pulses for the next fixed interval to trigger the differential
signal of channel 0. Then, it stops comparing pulses when the total trigger count is reached.
27-12
Data type
Property
U16
Number
I32
Pulse
U16
Option
U16
Pulse number
U32
Amount
EtherCAT Programming Guide
Description
Card No.
Start position of the compare.
Direction
0: forward
1: backward
Pulse interval for carrying out the compare.
Triggering count of the compare function.
.
March, 2017

Hide quick links:

Advertisement

Table of Contents
loading