Operation of Pulse Module (R1-EC5621D0)
20.2 _ECAT_Slave_R1_EC5621_Set_Input_Mode
Syntax
U16 PASCAL _ECAT_Slave_R1_EC5621_Set_Input_Mode (U16 CardNo, U16 AxisNo,
U16 SlotNo, U16 RangeMode)
Purpose
This is for setting the mode of pulse input.
Parameter
Name
CardNo
AxisNo
SlotNo
Mode
Example
U16 Status = 0;
U16 CardNo=16, AxisNo =1, SlotNo=0;
U16 Mode=1;
Status= _ECAT_Slave_R1_EC5621_Set_Input_Mode (CardNo, AxisNo, SlotNo, Mode);
20-4
Data type
Property
U16
Number
U16
Number
U16
Number
U16
Option
EtherCAT Programming Guide
Description
Card number
Node ID
Slot ID
0: A/B Phase
1: CW/CCW
2: PLS/DIR