Sierra Trainer Generation Commands

5.14.8 Generation Settings

Setting
Global Settings
GenerationMode
MultiSpeedMode
Output Disable
SupportSNW1
SupportSNW2
PauseTrnScrmblr.
ReconnectOnRun
AdvanceConnect
OutputOffAfterDC
 
Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual
Default
Value
Description
>>>>>
Generation Mode ‐ must be defined or no generation
will take place. Possible Values:
GEN_MODE_SATA_HOST GEN_MODE_SATA_DEVICE
GEN_MODE_SAS_INITIATOR
GEN_MODE_SAS_TARGET
Default Value: GEN_MODE_ERROR ‐ undefined mode
0
When set, the change of speed within Generation
block is allowed with following syntax: set Speed =
LINK_SPEED_1_5G / LINK_SPEED_3G /
LINK_SPEED_6G
0
This very poorly named register bit forces the Trainer
to output data. It is a little like the output_on script
command except that its effect cannot be undone for
the duration of the script. If this is turned on, none of
the out‐of‐band commands will work, as the output
enable is forced on.
1
When set, in "Connect command" SNW1 will be tried
in Speed Negotiation phase
Can only be set outside Generation block.
1
When set, in "Connect command" SNW2 will be tried
in Speed Negotiation phase.
Can only be set outside Generation block.
0
When set, the generator pauses the Idle scrambler of
Train/TrainDone pattern.
0
When "AdvanceConnect" and "ReconnectOnRun"
are set, the "Connect" command forces the Trainer
to disconnect the physical link before executing the
"Connect" command.
When "AdvanceConnect" is not set, this setting does
not affect the Trainer.
0
When set, the Trainer uses the
"PHY Capability" and "SupportSNW" settings,
instead of the "Set Speed" settings, for executing the
"Connect" command.
On
If set to On, Trainer puts DC Idle on line when it
detects sync lost on the link.
Off
Teledyne LeCroy