Clearing The Log File; Transponder Functions; Configuring The Transponder Settings - Teledyne BENTHOS UDB-9000 User Manual

Universal deck box
Table of Contents

Advertisement

UDB-9000 Universal Deck Box - UDB-9000-M (Portable) and UDB-9000-MR (Rack Mount) Configurations
To export the log file:
1. Touch Logging Options in the Modem Comms screen on any of the
three tabs.
The Modem Comms Logging Options window opens as shown in
Figure 4-45 on page 4-32.
2. Touch Dump Log to COM2.
The log file is exported. When exporting is complete an information
window temporarily opens with the message "Done outputting Log."

Clearing the Log File

To clear the log file:
1. Touch Logging Options in the Modem Comms screen on any of the
three tabs.
The Modem Comms Logging Options window opens as shown in
Figure 4-45 on page 4-32.
2. Touch Clear Log.
The log file cleared.

Transponder Functions

The UDB-9000 can be used to acquire and display ranges to any Teledyne
Benthos manufactured acoustic transponder or release, and similarly, to
those manufactured by EdgeTech/EG&G and URI, or to any transponder that
replies to pings in the frequency range 7–16 kHz. Before acquiring ranges,
always ensure that the transducer is connected.

Configuring the Transponder Settings

Before acquiring ranges to transponders, a number of transponder settings
need to be made. These settings include the deck box transmit frequency,
transmit and receive pulse widths, turn-around-time (TAT), and timeout.