Teledyne Sierra M6-2 User Manual page 184

Sas/sata protocol analyzer
Table of Contents

Advertisement

Teledyne LeCroy
Figure 2.195: SATA: Settings Dialog
The settings dialog allows you to set the Analysis update interval and define the counter
mode.
1. Choose the Update Interval in the range of 1 ms to 245 minutes.
2. Set the Counter Mode to either Cumulative or Instantaneous.
3. Set the Analyzer Speed for each port used.
4. To disable descrambling, check the Disable Descrambling check box.
5. Enter a value for Primitive Response Timeout.
6. Choose the Align Transmission Period by checking the corresponding option
7. To select Protocol Errors to exclude from the analysis, click the Protocol Error Mask 
8. To save the analysis result for later review, check Save to file and enter the path in
9. To include a descriptive note about the project, click the Notes tab and enter
182
Cumulative causes the measurement counters to continually increment>
Instantaneous causes the measurement counters to reset for each Update interval.
button.
button and check any or all of the protocol errors to exclude. See
on page
71.
which to save the result.
information in the Notes dialog. See
"Add a Project Note" on page
Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual
Performance Analysis
"Protocol Errors"
116.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents