External Trig Out Setting - Teledyne Sierra M6-2 User Manual

Sas/sata protocol analyzer
Table of Contents

Advertisement

Projects
this, the code violation is not triggered during the speed negotiation phase, but is
triggered if the violation happens after the speed negotiation phase.

External Trig Out Setting

The Analyzer can send a Low or High external signal when a trigger occurs. Under Setup 
select External Trig Setting to choose External Trig Out Setting: High Active, Low Active, or
Toggle from High to Low or Low to High once (3.3 V output). Enter the External TrigOut
pulse width.
The pulse width is programmable in the software. The Voltage level is 0 to +3.3 Volt. The
trigger out is derived by NL17SZ126 buffer. The delay for OOB traffic external trigger out is
330 ns. The delays for non OOB external trigger out are:
The delays for external trigger out with OOB traffic is 330 ns.
 
Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual
6G ~ 370 ns
3G ~ 540 ns
1.5G ~ 850 ns
Teledyne LeCroy