The lateral offset information used to generate the outputs is provided from the DeepView external
output. If the external output is disabled via DeepView, the analogue output will not provide any
outputs.

4.2.5.2 Analogue Output DIP Switch Settings

The analogue output configuration can be modified using the DIP switches located on the underside of
the Comms Enclosure facing the rear of the Panel PC. These switches are not accessible during
normal operation. To access the DIP switches, the Comms Enclosure needs to be removed from the
Panel PC.
The following steps outline how to correctly remove the Comms Enclosure:
The external Comms Enclosure has connections from the Panel PC routed
through the underside of the enclosure. Take care removing the enclosure from
the Panel PC mounts ensuring these connections are not damaged.
1. Remove the transit case lid using the 4 x fixings provided.

Figure 4-6: Removing the transit case lid

2. Remove the 8 x fixings from the Panel PC attaching it to the angled bracket secured to the
transit case base.
DPN 402196 Issue 4.1
NOTE
© Teledyne TSS
4 – Electrical Installation
4- 17