Teledyne Sierra M6-2 User Manual page 141

Sas/sata protocol analyzer
Table of Contents

Advertisement

Emulation
Figure 2.138: Specify Patterns
Add Wait for Any Frame
Insert this instruction and set an expiration time and a label for the Goto. This instruction
causes the Initiator program to go to the specified label if any frame occurs prior to the
expiration time. If the expiration time occurs first, the Initiator program goes to the next
step.
Figure 2.139: Wait
Add Wait for PS (SAS only)
Insert this instruction and select PS_ACK or PS_NAK. Set an expiration time and a label for
the Goto. This instruction causes the emulator to go to the specified label if any frame
occurs prior to the expiration time. If the expiration time occurs first, the emulator goes
to the next step.
Figure 2.140: SAS: Wait for PS
Add Wait for Power Management (SATA only)
Insert this instruction and select PM_ACK or PM_NAK. Set an expiration time and a label
for the Goto. This instruction causes the emulator to go to the specified label if any frame
occurs prior to the expiration time. If the expiration time occurs first, the emulator goes
to the next step.
 
Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual
Teledyne LeCroy
139

Hide quick links: