Advanced Mode (User‐Defined)
2.7.2

Multi-Link Triggering

You can set different triggering for each link. To set different trigger conditions for a link,
check the Multi Sequencer check box and select the link for setup from the Port drop‐
down list. Clicking the Make Same as Current button displays a warning: all sequencers
will be changed to have same states as current sequencer. Click Yes to do so.
Figure 2.111: Multi-Link Triggering Setup
2.7.3

Set Timers

You can set and use up to three timers for triggering. You can set each timer for each state
or continue from a timer set in the previous state. The timer defined for a particular state
starts when entering that state. To set timers, click the ellipses in the Timer field in each
state and define each of the timers in the Set Timers dialog.
Figure 2.112: Set Timers Dialog
Note:
Three timers are available. You have to set and start each timer in order to continue the next
timer. For example, you have to start Timer 1, continue it, then set Timer 2 in order to continue
it. It will not allow you to continue Timer 2 until you first set it.
2.7.4

Timeout

The timeout trigger allows triggering based on the occurrence or non‐occurrence of two
events within a pre‐defined period of time. Patterns can be added to the Start Events and
End Events list. An occurrence of a pattern of the Start Events list starts the timer, or
 
Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual