Target Emulator Settings (Sas) - Teledyne Sierra M6-2 User Manual

Sas/sata protocol analyzer
Table of Contents

Advertisement

Target and Device Emulation

2.12.11 Target Emulator Settings (SAS)

Click the Settings tab to display the Target Emulator Settings dialog.
Figure 2.219: SAS: Target Emulator Settings Dialog
The Settings page opens with a default set of values, which you can modify. To return to
these values, click the Default Settings button.
Define the Target
Enter a SAS Address, Data Frame Payload Size, Logical Block Size, Linked Command 
Expired Time, and ALIGN Transmission Period in the corresponding text box. Check
Calculate capacity based on Mode pages or enter a value for Number of Blocks.
Media Settings
Enter a value for Average Access Time to simulate Seek/Access time delay of a real device.
Enter a Number of Writable Areas. Define a Start and an End Address, click the down
arrow under the Area Type, and choose Normal Writable, Circular Writable, or Non‐
Writable.
Note:
To set and get the settings of Media Settings Area Types, use these two functions:
SetMediaAreaAttribute(int nAreaIndex, int nStartAddress,
int nEndAddress, TrgEmulMediaAreaTypeEnum eAreaType, int* pnErrorCode)
GetMediaAreaAttribute(int nAreaIndex, int* pnStartAddress,
int* pnEndAddress, TrgEmulMediaAreaTypeEnum* peAreaType)
nAreaIndex: Specifies the (zero base) index of the Area.
Note:
The Number of Areas should be set by the SetNumberOfMediaArea function prior to calling
these functions.
 
Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual
Teledyne LeCroy
207