Teledyne Sierra M6-2 User Manual page 462

Sas/sata protocol analyzer
Table of Contents

Advertisement

Teledyne LeCroy
Sending OpenAddressFrame Using
Standard Frame Templates
SendOpenAddressFrameSTP {
SourceAddress
DestinationAddress = { 500062B0 00000030
}
# RawData with variables embedded
RawData {
K28.5 D24.0 D30.0 D01.4
@variableName1
50 00 62 B0
00 00 00 30
50 08 05 EF
$C
00 00 00 01
00 00 00 00
SendCRC
K28.5 D24.0 D07.3 D31.4 }
}
When there are variable values in RawData, you must include SendCRC command instead
of last dword. Otherwise, wrong CRC value will be sent. The constraints are:
460
= { 500805EF FFFF0041 }
ArbitrationWaitTime = 0x1
AccessZoneManagement= 0x0
SourceZoneGroup
ConnectionRate
= 0x8
Features
= 0x0
InitiatorConnectionTag = 0x1
InitiatorPort
= 0x0
MoreCompatibleFeatures = 0x0
PathwayBlockedCount = 0x0
# CRC = 0x050F19E0 # good crc }
Variables are not allowed on First and LAST DWORD (instead of start/end
frames).
SendCRC is only supported on last DWORD before end of frame.
Raw 10 bits codes. This definition might cause running disparity errors.
Sending the Same
OpenAddressFrame Using Raw Data
Mechanism
Set ScramblingMode =
SCRAMBLING_MODE_SAS
RawData {
K28.5 D24.0 D30.0 D01.4
21
50
= 0x0
00
50
FF
00
00
05
K28.5 D24.0 D07.3 D31.4 }
* CRC is inserted manually
Sierra M6‐2 SAS/SATA Protocol Analyzer User Manual
Sierra Trainer Generation Language
08
00
01
00
62
B0
00
00
30
08
05
EF
FF
00
41
00
00
01
00
00
00
0F
19
E0

Hide quick links: