monitoring only specified traffic instead all traffic on the interface. This feature is
particularly useful when looking for malicious traffic. It is available for Layer 2 and
Layer 3 ingress and egress traffic. You may specify traffic using standard or
extended access-lists. This mechanism copies all incoming or outgoing packets on
one port and forwards (mirrors) them to another port. The source port is the
monitored port (MD) and the destination port is the monitoring port (MG).
Related
permit (for Standard IPv6 ACLs)
Commands

seq (for IPv6 ACLs)

Assign a sequence number to a deny or permit the filter in an IPv6 access list while creating the filter.
Syntax
seq sequence-number {deny | permit} {ipv6-protocol-number |
icmp | ip | tcp | udp} {source address mask | any | host ipv6-
address} {destination address | any | host ipv6-address}
[operator port [port]] [count [byte]] [log [interval minutes]
[threshold-in-msgs [count]] [monitor]
To delete a filter, use the no seq sequence-number command.
Parameters
log
threshold-in
msgs count
interval
minutes
monitor
Defaults
By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
The default frequency at which ACL logs are generated is five minutes. By default,
flow-based monitoring is not enabled.
Command
ACCESS-LIST
Modes
Command
Version 9.5(0.1)
History
Version 9.4(0.0)
IPv6 Access Control Lists (IPv6 ACLs)
– configures a filter to forward IPv6 packets.
(OPTIONAL) Enter the keyword log to enable the triggering
of ACL log messages.
(OPTIONAL) Enter the threshold-in-msgs keyword
followed by a value to indicate the maximum number of ACL
logs that can be generated, exceeding which the generation
of ACL logs is terminate with the seq, permit, or deny
commands. The threshold range is from 1 to 100.
(OPTIONAL) Enter the keyword interval followed by the
time period in minutes at which ACL logs must be generated.
The interval range is from 1 to 10 minutes.
(OPTIONAL) Enter the keyword monitor when the rule is
describing the traffic that you want to monitor and the ACL
in which you are creating the rule is applied to the monitored
interface.
Introduced on the Z9500.
Added support for flow-based monitoring on the S4810,
S4820T, S6000, and Z9000 platforms.