Dell Z9100-ON Installation Manual

Open networking
Hide thumbs Also See for Z9100-ON:
Table of Contents

Advertisement

Dell Networking Z9100–Open Networking
(ON) Installation Guide
October 2015

Advertisement

Table of Contents
loading

Summary of Contents for Dell Z9100-ON

  • Page 1 Dell Networking Z9100–Open Networking (ON) Installation Guide October 2015...
  • Page 2 WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell and the Dell logo are trademarks of Dell Inc.
  • Page 3: Table Of Contents

    Introduction ..............................7 Features ..........................7 Physical Dimensions ............................8 System Status ............................8 LED Displays ..................8 LED Behavior on the Z9100-ON System ............................10 Prerequisites ........................11 Z9100–ON Configurations 3 Site Preparations....................12 ............................12 Site Selection ..........................12 Cabinet Placement .............................13 Rack Mounting .....................
  • Page 4 ...................31 Accessing the MicroUSB-B Console Port ........................31 Mounting the USB Storage ..........32 Before You Install an Operating System on the Z9100-ON System ..............32 Example of the Grub BootloaderExample of ONIE ................33 ONIE Service Discovery on the Z9100–ON System 8 Specifications...................... 35 ........................
  • Page 5: About This Guide

    • Dell Open Networking Troubleshooting Guide • Dell Networking Command Line Reference Guide for the Z9100–Open Networking (ON) System • Dell Networking Configuration Guide for the Z9100–Open Networking (ON) System NOTE: For the most recent documentation, visit Dell Support: http://www.dell.com/support.
  • Page 6: The Z9100-On System

    The following sections describe the Dell Networking Z9100–ON system. Introduction Z9100-ON is a 1 rack unit compact 10/25/40/50/100 GbE switch. The system includes 32 fixed quad form-factor pluggable 28 (QSFP28) optics for 40/100 GbE aggregation and 10/25/40/50 GbE top of rack (ToR) and end of row (EoR) applications.
  • Page 7: Features

    • Removable fans • Standard 1U chassis Physical Dimensions The Z9100-ON has the following physical dimensions. • 434 x 320 x 44 mm (W x D x H) • 17.09 x 12.60 x 1.74 inches (W x D x H)
  • Page 8: System Status

    The Z9100–ON includes LED displays on the I/O side of the system. NOTE: If you are installing third-party software, for LED information, see your third-party operating software documentation. LED Behavior on the Z9100-ON System The following Z9100–ON system LED behavior is seen during open networking installation environment (ONIE) operations.
  • Page 9 Table 1. Z9100–ON LED Behavior Description • Solid green — Normal Operation System Status/Health LED • Blinking green — Booting • Solid amber — Critical system error • Blinking amber — Non-critical system error (fan failure or power supply failure) •...
  • Page 10: Prerequisites

    Solid green — System is the Master of the stack or a standalone unit Prerequisites The following is a list of components required for successful installation of the Z9100-ON. NOTE: Detailed installation instructions for the Z9100-ON are provided in Site Preparations Install the Z9100-ON.
  • Page 11: Z9100-On Configurations

    • Additional power supply unit • Additional fan module • Additional mounting brackets (if installing in a four-post rack or cabinet) Z9100–ON Configurations You can order the Z9100–ON system in several different configurations. You can order the following supported hardware components. •...
  • Page 12: Site Preparations

    Site Selection Install Dell Networking equipment in restricted access areas. A restricted access area is one in which service personnel can only gain access using a special tool, lock, key or other means of security and access is controlled by the authority responsible for the location.
  • Page 13: Rack Mounting

    Do not mix reverse and normal airflows in a single Z9100–ON chassis. For proper ventilation, position the Z9100-ON in an equipment rack (or cabinet) with a minimum of 5 inches (12.7 cm) of clearance around the exhaust vents. When you install two Z9100-ON systems near each other, to permit proper airflow, position the two chassis at least 5 inches (12.7 cm) apart.
  • Page 14: Storing Components

    Storing Components If you do not install your Z9100–ON and components immediately, Dell Networking recommends properly storing the system and all optional components by following these guidelines. • Storage location temperature must remain constant. The storage range is from -40° to 158°F (-40°C to 70°C).
  • Page 15: Install The Z9100-On

    Unpack the Z9100-ON System NOTE: Before unpacking the system, inspect the container and immediately report any evidence of damage. When unpacking the Z9100-ON switch, make sure that the following items are included: • One Z9100-ON switch • One RJ-45 to DB-9 female cable •...
  • Page 16: Install Rack Or Cabinet Hardware

    You may either place the switch on a rack shelf or mount the switch directly into a 19" wide, EIA-310- E- compliant rack (four-post, two-post, or threaded methods). The Dell ReadyRails™ system is provided for 1U front-rack and two-post installations.
  • Page 17: Configuring A Two-Post Flush-Mount

    Figure 5. 1U Tool-less Configuration Align and seat the front flange pegs in the holes on the front side of the vertical post. See item 2. Repeat this procedure for the second rail. To remove each rail, pull on the latch release button on each flange ear and unseat each rail. See item 3.
  • Page 18: Configuring A Two-Post Center-Mount

    Figure 6. Two-Post Flush-Mount Configuration Attach one rail to the front post flange with two user-supplied screws. See item 2. Slide the plunger bracket forward against the vertical post and secure the plunger bracket to the post flange with two user-supplied screws. See item 3. Repeat this procedure for the second rail.
  • Page 19: Configuring A Four-Post Thread

    Figure 7. Two-Post Center-Mount Configuration Slide the back bracket towards the post and secure it to the post flange with two user-supplied screws. See item 2. Repeat this procedure for the second rail. Configuring a Four-Post Thread To configure a four-post thread installation, follow these steps. For this configuration, remove the flange ear castings from each end of the ReadyRails assemblies.
  • Page 20: Install The Z9100-On System

    Installing a 1U Front-Rack Configure the rails that are attached to the system. Attach the switch rails (inner chassis members) to the Z9100-ON system. The following illustration, item 3, shows the detail for the front standoff with the locking tab.
  • Page 21 Figure 9. Attaching the Switch Rails After you have installed both switch rails, line them up on the previously mounted ReadyRails and slide the switch in until it is flush with front of rack. About three inches before you fully insert your system, the rail locking feature engages to keep the switch from inadvertently sliding out of the rack and falling.
  • Page 22: Attaching The Ground Cable (Optional)

    To attach the ground cable to the chassis, use a single M4x0.7 screw. The cable itself is not included with the Z9100–ON system. To properly ground the chassis, Dell Networking recommends using a 6 AWG one-hole lug, #10 hole size, 63" spacing (not included in shipping). The one-hole lug must be a UL recognized, crimp-type lug.
  • Page 23: Remove The Sfp+ Optics

    Power Up the System Supply power to the Z9100–ON after it is mounted in a rack or cabinet. Dell Networking recommends re-inspecting your system prior to powering up. Verify the following: • The equipment is properly secured to the rack and properly grounded (optional).
  • Page 24: Power Supplies

    NOTE: If you use a single PSU, install a blank plate in the other PSU slot. Dell Networking recommends using power supply 2 (PSU2) as the blank plate slot. Use a #1 Philips screw driver to install the blank plate.
  • Page 25: Installing An Ac Or Dc Power Supply

    NOTE: If you use a single PSU, install a blank plate in the other PSU slot. If you are only using one power supply, Dell recommends installing the power supply in the first slot (PSU1) and installing a blank plate in the second slot (PSU2).
  • Page 26: Replacing An Ac Or Dc Power Supply

    NOTE: If you use a single PSU, install a blank plate in the other PSU slot. If you are only using one power supply, Dell recommends installing the power supply in the first slot (PSU1) and installing a blank plate in the second slot (PSU2).
  • Page 27: Fans

    In addition to the power supply modules, you can order and install fan modules separately. The Z9100-ON supports two airflow direction options. Do not mix airflow types in a chassis; you can use only a single airflow direction in a chassis. If the airflow directions are mismatched, the Z9100-ON issues an alarm.
  • Page 28: Installing A Fan Module

    Figure 13. Z9100–ON Fan Modules Fan Modules Installing a Fan Module The fan modules in the Z9100–ON are field replaceable. Module slot 1 is on the left side of the chassis, module slot 2 is in the middle of the chassis, and module slot 3 is on the right side of the chassis.
  • Page 29: Replacing A Fan Module

    Slide the fan module out of the bay. Slide the replacement module into the bay. After Installing the Z9100–ON After you have securely installed and powered on the Z9100-ON, to configure your system, see your third-party ONIE-compatible OS or Dell Networking OS documentation. Fans...
  • Page 30: Management Ports

    Besides the 10/25/40/50/100 GbE RJ-45 ports, the Z9100–ON system provides several ports for management and storage. Accessing the RS-232 Console Port The RS-232 console port is on the I/O-side of the Z9100-ON chassis (as shown in the following illustration). Figure 15. Z9100–ON RS-232 Console Ports •...
  • Page 31: Accessing The Microusb-B Console Port

    Accessing the MicroUSB-B Console Port The MicroUSB type B console port is on the I/O side of the Z9100-ON. The terminal settings are the same for the serial console port and the RS-232/RJ-45 console port: • 115200 baud rate •...
  • Page 32: Before You Install An Operating System On The Z9100-On System

    Before You Install an Operating System on the Z9100-ON System After powering on the Z9100-ON system, it goes through a power-on self-test (POST). POST runs every time the switch is initialized and checks the hardware components to determine if the switch is fully operational before booting.
  • Page 33: Onie Service Discovery On The Z9100-On System

    For downloading and updating ONIE from a URL and erases any installed OS ONIE: Diag ONIE Run Diagnostic package for Z9100-ON During the initial setup, the system boots to ONIE Install. ONIE Install boots with ONIE Discovery to the console (ONIE:).
  • Page 34 The ONIE Install environment uses DHCP to assign an IP address to the management interface (eth0). If that fails, it uses the default IP address 192.168.3.10/255.255.255.0. To display the IP address, use the ifconfig eth0 command, as shown in the following example. ATTENTION REVIEWERS: Is this output still correct? ONIE:/ # ifconfig eth0...
  • Page 35: Specifications

    Specifications This chapter lists the Z9100–ON specifications. CAUTION: Operate the product at an ambient temperature not higher than 113°F (45°C). CAUTION: Lithium Battery Caution: There is a danger of explosion if the battery is incorrectly replaced. Replace only with same or equivalent type of battery. Dispose of the batteries according to the manufacturer's instructions.
  • Page 36: Ieee Standards

    Parameter Specifications Maximum non-operational altitude No performance degradation to 35,000 feet (10,668 meters) Shock SV0115 — ODM ATTENTION REVIEWERS: Please review this table. Table 9. AC Power Requirements Parameter Specifications Power Supply 100–240 VAC 50/60 Hz 3A @ 100vac Maximum Current Draw Per System 2A @ 200vac PSU Maximum Power Capability 224.4 Watts...
  • Page 37: Agency Compliance

    Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Dell Networking is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications in the equipment.
  • Page 38: Japan: Vcci Compliance For Class A Equipment

    Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. WARNING: Use the AC power cords with Dell Networking equipment only. Do not use Dell Force10 AC power cords with any unauthorized hardware.
  • Page 39: Korean Certification Of Compliance

    Korean Certification of Compliance Figure 19. Korean Certification of Compliance Figure 20. Korean Package Label Safety Standards and Compliance Agency Certifications • CUS UL 60950-1, 2nd Edition • CSA 60950-1-03, 2nd Edition • EN 60950-1, 2nd Edition • EN 60825-1, 1st Edition •...
  • Page 40: Electromagnetic Compatibility (Emc)

    Networking encourages owners of information technology (IT) equipment to responsibly recycle their equipment when it is no longer needed. Dell Networking offers a variety of product return programs and services in several countries to assist equipment owners in recycling their IT products.
  • Page 41 EEE on the environment and human health due to the potential presence of hazardous substances in EEE. Dell Networking products, which fall within the scope of the WEEE, are labeled with the crossed-out wheelie-bin symbol, as shown above, as required by WEEE.
  • Page 42: Technical Support

    Accessing Dell Support Services The URL for Dell Support is http://www.dell.com/support. You must have a user id and password to access Dell Support services. If you do not have a user id and password, you can request these at the website.
  • Page 43: Requesting A Hardware Replacement

    • Using the Create Service Request form on the Support page. • Contacting Dell Networking directly by email or by phone. • Provide the following information when using email or phone: – Part number, description, and serial number of the component.

Table of Contents