Modem Control Register (Mcr) - Intel PXA255 Developer's Manual

Intel computer hardware user manual
Hide thumbs Also See for PXA255:
Table of Contents

Advertisement

Table 17-15. LSR Bit Definitions (Sheet 2 of 2)
Physical Address
0x4160_0014
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
Reset ?
?
?
?
?
?
Bits
Name
3
2
1
0
17.5.12

Modem Control Register (MCR)

The MCR, shown in
modem or data set. The MCR also controls the loopback mode. Loopback mode must be enabled
before the UART is enabled.
This is a read/write register. Ignore reads from reserved bits. Write zeros to reserved bits.
Intel® PXA255 Processor Developer's Manual
Line Status Register (LSR)
reserved
?
?
?
?
?
?
?
FRAMING ERROR
FE indicates that the received character did not have a valid stop bit. FE is set when the bit
following the last data bit or parity bit is detected as 0. If the LCR had been set for two stop
bit mode, the receiver does not check for a valid second stop bit. The FE indicator is reset
when the processor reads the LSR. The UART re-synchronizes after a framing error. To do
FE
this it assumes that the framing error was due to the next start bit, so it samples this "start"
bit twice and then reads in the "data". In FIFO mode, FE shows a framing error for the
character at the front of the FIFO, not for the most recently received character.
0 = No framing error
1 = Invalid stop bit has been detected
PARITY ERROR
Indicates that the received data character does not have the correct even or odd parity, as
selected by the even parity select bit. PE is set when a parity error is detected and is
PE
cleared when the processor reads the LSR. In FIFO mode, PE shows a parity error for the
character at the front of the FIFO, not the most recently received character.
0 = No parity error
1 = Parity error has occurred
OVERRUN ERROR
In non-FIFO mode, OE indicates that data in the Receive Buffer register was not read by the
processor before the next character was received. The new character is lost. In FIFO mode,
OE indicates that all 64 bytes of the FIFO are full and the most recently received byte has
OE
been discarded. The OE indicator is set when an overrun condition is detected and cleared
when the processor reads the LSR.
0 = No data has been lost
1 = Received data has been lost
DATA READY
DR is set when a complete incoming character has been received and transferred into the
Receive Buffer register or the FIFO. In non-FIFO mode, DR is cleared when the receive
DR
buffer is read. In FIFO mode, DR is cleared if the FIFO is empty (last character has been
read from Receive Buffer register) or the FIFO is reset with FCR[RESETRF].
0 = No data has been received
1 = Data is available in RBR or the FIFO
Table
17-16, uses the modem control pin nRTS to control the interface with a
?
?
?
?
?
?
?
?
Description
Hardware UART
PXA255 Processor Hardware UART
8
7
6
5
4
3
?
?
?
0
1
1
0
0
2
1
0
0
0
0
17-21