Intel PXA255 Developer's Manual page 395

Intel computer hardware user manual
Hide thumbs Also See for PXA255:
Table of Contents

Advertisement

Table 11-2. ICCR0 Bit Definitions (Sheet 2 of 2)
0x4080_0000
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9
Reset
0
0
0
0
0
0
Bits
Name
3
2
1
LBM
0
Intel® PXA255 Processor Developer's Manual
Fast Infrared Communication Port
Control Register 0 (ICCR0)
reserved
0
0
0
0
0
0
0
Transmit enable.
0 = FICP transmit logic disabled.
1 = FICP transmit logic enabled if ICCR0[ITR] is set.
All other control bits must be configured before TXE is set. An SIP is transmitted
immediately after the transmitter is enabled. If the transmit FIFO is empty, preambles are
sent until data is placed in the FIFO.
TXE
If TXE is cleared while it transmits data, transmission stops immediately, all data in the
transmit FIFO and serial output shifter is cleared, and the SIU takes control of the transmit
data pin.
While communication is normally half-duplex, it is possible to transmit and receive data at
the same time. Duplex communication is used for testing in Loopback Mode.
If TXE is used to clear the transmitter, check ICSR1[TBY] to ensure the transmitter is not
busy before the transmitter is re-enabled.
Transmit FIFO underrun select.
A transmit FIFO underrun can either end the current frame normally, or transmit an abort.
0 = Transmit FIFO underrun causes CRC, stop flag, and SIP to be transmitted, and masks
transmit underrun interrupt generation.
TUS
1 = Transmit FIFO underrun causes abort to be transmitted, and generates an interrupt.
Clearing ICCR0[TUS] does not affect the current state of ICSR0[TUR] or prevent TUR from
being set or cleared by the transmit FIFO. After an abort, a SIP is transmitted followed by
16 preambles. Preambles continue until data is in the FIFO.
Loopback mode.
Used for testing FICP.
0 = Normal FICP operation enabled.
1 = Output of transmit serial shifter is connected to input of receive serial shifter.
IrDA transmission.
ITR
0 = ICP unit is not enabled.
1 = ICP unit is enabled.
Fast Infrared Communication Port
0
0
0
0
0
0
0
0
Description
Fast Infrared Communication Port
8
7
6
5
4
3
0
0
0
0
0
0
0
0
2
1
0
0
0
0
11-9

Hide quick links: