Ip Bfd Receive - Alcatel-Lucent 060321-10, Rev. B Cli Reference Manual

Omniswitch series
Table of Contents

Advertisement

BFD Commands

ip bfd receive

Configures the global receive time interval for BFD control packets. This command specifies the mini-
mum amount of time BFD waits to receive control packets before determining there is a problem.
ip bfd receive receive_interval
Syntax Definitions
receive_interval
Defaults
parameter
receive_interval
Platforms Supported
OmniSwitch 10K
Usage Guidelines
The minimum receive time interval is also configurable at the BFD interface level. Note that configur-
ing the global value with the ip bfd receive command does not override the value set for the interface
using the ip bfd interface receive command.
The global receive time interval serves as the default interval value for a BFD interface. The default
interval value is overridden when a specific value is configured for the interface.
Examples
-> ip bfd receive 500
Release History
Release 7.1.1; command was introduced.
Related Commands
ip bfd interface receive
show ip bfd
MIB Objects
alaBfdGlobalRxInterval
OmniSwitch CLI Reference Guide
The receive time interval, in milliseconds. The valid range is 100–999.
default
300 milliseconds
Configures the receive time interval for a specific BFD interface.
Displays the BFD global status and general configuration parameters.
March 2011
ip bfd receive
page 14-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omniswitch 10k

Table of Contents