BFD Commands

ip bfd echo-interval

Configures the global BFD echo packet time interval. The echo function is available with the asynchro-
nous mode. Echo packets are transmitted to BFD peers to see if they loop back to the peer from which
they originated.
ip bfd echo-interval echo_interval
Syntax Definitions
echo_interval
Defaults
parameter
echo_interval
Platforms Supported
OmniSwitch 10K
Usage Guidelines
The echo packet time interval is also configurable at the BFD interface level. Note that configuring the
global value with the ip bfd echo-interval command does not override the value set for the interface
using the ip bfd interface echo-interval command.
The global echo packet time interval serves as the default interval value for a BFD interface. The
default interval value is overridden when a specific value is configured for the interface.
Examples
-> ip bfd echo-interval 500
Release History
Release 7.1.1; command was introduced.
Related Commands
ip bfd interface echo-interval
show ip bfd
MIB Objects
alaBfdGlobalEchoRxInterval
OmniSwitch CLI Reference Guide
The echo time interval, in milliseconds. The valid range is 100–999.
default
300 milliseconds
Configures the echo packet time interval for a BFD interface.
Displays the BFD global status and general configuration parameters.
March 2011
ip bfd echo-interval
page 14-7