Sizing the external fuse (Prefuse).
When using 115V supply voltage:
To met UL requirements, the prefuse must be a class RK5 such as the type FRN-R-10
(10Amp.) from manufacturer: Cooper Bussmann INC.
When using 230V supply voltage:
Melt fuse: T6.3A@230VAC type gG, Do or Dz in the phase line Rated for 600V/150kA.
Automatic fuse: T6.3A@230VAC Class D.
3.2.11
Connecting an external power dump resistor
CM
PE
TT1173GB
The internal power dump can absorb up to 6W continuously and 1.4kW peak, which is
considered as appropriate for most applications.
However should a situation occur in which the connected load inertia is too large or the
deceleration too fast, the internal power dump will not be able to absorb all the returned
energy and will report the error message "regenerative overload".
In this situation the only possible solutions are as follows:
1. Decrease the acceleration/deceleration parameter.
2. Lower the attached load inertia.
3. Connect an external power resistor.
The drawing above shows how to connect an external power resistor. A wirewound
type is recommended since it will be able to absorb higher peak power than other types
of resistors.
Warnings:
94
Power Supply
MAC400 with external power dump connection.
PD
BO
Ensure that the resistor value is between 33 to 68 Ohm/50W since the
output otherwise can be damaged. Also avoid short-circuit of the output.
CAUTION
shock. Disconnect all power and
wait 5 min. before servicing
JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
Note ! : Its only necessary to
connect screen to signal source.
R
Screen
Use a value of 33
to 68 Ohm/50W
Wirewound
Shielding/housing must
be connected to earth
Terminal description for the "Dump" connector.
CM =
Common. Is internally connected to the ground of the DC bus.
Is only intended to be used if multiple motors share DC-bus.
BO =
Bus output. The internal DC bus is connected to this terminal.
PD =
Power Dump output. Behind this terminal is placed a switch
(IGBT transistor) which connect the terminal to the internal
bus ground if the voltage become higher than 400VDC.
- Risk of electric
Only MAC400
PD activated
BO-PD (V)
when voltage
exceeds 400V
Energy fed back from
Voltage (V)
the motor to the DC bus
Nom. 325VDC
Velocity
Time
400V
Time