5.6 Expansion Mod. MAC00-FC2/FC4/FC41
5.6.8
Necessary accessories to MAC-FC2/FC4/FC41:
On our web page
the modules, in the menu Field bus Interface Specifications Files.
EDS means Electronic Data Sheet. This file contains the information about the module
settings, that is required to configure the setup and program in the master.
The module is a slave module on the CAN-bus, the master can be for example a PLC or
a PC. If you are using a PLC as master, then make sure that it is provided with a CAN-
open® communications module, and that the correct programming tools are available.
For getting support to the PLC master, it is more rewarding to use the PLC vendor.
If you are using a PC as master JVL have some tools that can help you when you are in-
stalling and using the MAC00-FC2/FC4/FC41.
The latest firmware for the MAC00-FC2/FC4/FC41 module is in the menu downloads/
firmware. In the menu for programs you can find the program CanOpen Explorer, this
is a free-ware program.
The CanOpen Explorer program can be used to load the EDS file, and operate with the
motor. The CanOpenExplorer program shall use a special dongle for communication
with the PC, see
be provided with a CANopen® communications module. In
vey of cables JVL can supply, for the CAN-bus.
The MacTalk program can be used to monitor various operations and make the initial set
up on the motor see section 1.1 for setting up the MAC motor. In the menu for programs
you can find the program MacTalk, but be aware that this is not a free-ware program.
Please contact your JVL representative for further information.
5.6.9
EDS (Electronic data Sheet)
In order to give the user of CANopen® more support, are the device description avail-
able in a standardised way, and it gives the opportunity to create standardised tools for
configuration of CANopen® devices, designing networks with CANopen® devices and
managing project information on different platforms. The EDS file are ASCII-coded.
5.6.10
Preparing the hardware
To make the selection of the Baud-rate, Node-ID and Line termination on the MAC00-
FC2/FC4/FC41 module is it necessary to dismantle the module from the motor, and se-
lect it via the two Dip switches on the rear side of the module, notice that MAC00-FC4
include one more Dip switch, see
184
www.jvl.dk
section 5.6.16
Cable glands
CAN-open and I/O
connectors.
TT1069GB
JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
you can, under the downloads menu find the EDS file for
for further information about the dongle. The PC has to
section
5.6.12:
Dip Switches placed
on the rear side of the
module
section 6.14.1
there is a sur-
Internal circuit boards