5.6 Expansion Mod. MAC00-FC2/FC4/FC41
The drawing below shows the SW3 Dip-switch location. The various settings of SW3 is
shown on the previous page.
Switch description:
SW3
Dip 1
Dip 2
Dip 3
Dip 2
Dip 3
Dip 4
Dip 5
Dip 6
The factory default setting is:
SW3
Dip 1
Dip 2
Dip 3
Dip 4
Dip 5
Dip 6
JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
M12 Connectors
Mini dip-switch
(shown with default setting)
OFF
1
2
3
4
5
6
SW3
TT1072GB
Description
RS232 interface - transmit output
I/O terminal A
I/O terminal A
I/O terminal B
I/O terminal C
I/O terminal D
ON
OFF
Function
X
RS232 interface Enable
X
O2 (output 2)
X
X
Input 1
X
O1 output
X
O+ (output supply)
Dip switch location on the
MAC00-FC4 Expansion module
ON
SW3
Function
ON = Enable
DIP2=ON and DIP3=OFF:
AIN (Analogue input)
DIP2=OFF and DIP3=ON:
O2 (output 2)
DIP4=ON: Output 1
DIP4=OFF: Input 1
DIP5=ON: O1 output
DIP5=OFF: PL (positive limit input)
DIP6=ON: O+ (Output supply)
DIP6=OFF: NL (Negative limit input)
Dip Switch SW3
placed on the rear
side of the module
Internal circuit boards
Signal name
Tx
IOA
IOA
IOB
IOC
IOD
239