6.2
Nm
MAC400 Torque versus speed
5.0
4.0
3.0
2.0
1.0
0
1000
Nm
MAC800 Torque versus speed
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0
1000
362
Torque Curves
2000
2000
JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
Oz./Inch
708
566
425
283
142
RPM
3000
4000
>3600RPM =
Overspeed error
Oz./Inch
1133
991
850
708
566
425
283
142
RPM
3000
4000
>3600RPM =
Overspeed error
Only MAC400/800
Conditions:
Supply voltage = 90-240VAC
Ambient temperature < 40°C
Torque setting = 300% (max)
Load setting = 1.0
Operation above 3000 RPM
can be done, but the losses in
the motor makes it impossible
to operate in this area cyclicly.
Please be aware that an overspeed
error will occur if the speed gets
equal or higher than 3600 RPM.
= Peak torque
= Average torque
TT0992GB