5.10 Expansion module MAC00-P4/P5
5.10.6
RS232 - General description when using the MAC00-P4/5 module
The RS232 interface is consid-
ered the main interface to the
motor when the motor is set
up using the MacTalk win-
dows software from a PC or
from any kind of controller us-
ing a RS232 interface.
Note:The basic MAC motor
does not fully support RS232
since the interface signals are
only 5V levels. See also the ba-
sic description -
page
111.
When connecting the RS232
interface to a PC or control-
ler, the following rules must
be followed:
1
Only one motor can be
connected at the interface
line.
2
Use screened cable.
3
Ensure that GND is also
connected.
4
Ensure that all units have a
proper connection to safety ground (earth) in order to refer to the same potential.
5
The RS232 interface cable length should not exceed 10 metres.
Connectors:
To see the specific connector pin-out please see the chapter
-
Expansion MAC00-P4 connector description, page 305
-
Expansion MAC00-P5 connector description, page 308
A finished RS232 cable also exist. Please see
-
Cables for the MAC00-P4, page 307
-
Cables for the MAC00-P5, page 310
JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
RS232 connection between a PC or central controller
(for example a PC)
Serial interface,
TT1167GB
* Opto isolation is recommended if the Rs232 connection is a permanent installation.
to MAC400 with a MAC00-Px module.
Central
Make sure that all
involved units are
Controller
connected to the same
potential
Opto isolation *
Screen connected
to GND in each end
MAC400 Motor
with MAC00-Px
Rx
RS232
Tx
Interface
IGND
Power
Supply
Contr. Voltage CVI1
Main supply
or
or
Only MAC400-3000
Power supply
The terminal P+
do not exist on
MAC00-P5.
Use only CVI1
Max. 32VDC !
P+
P-
Mains 115/230VAC