5.6 Expansion Mod. MAC00-FC2/FC4/FC41
BUS1
Primary CANopen
connector.
M12 - 5pin male
connector including:
CANopen interface
BUS2
Second CANopen
connector
M12 - 5pin female
connector including:
CANopen interface
5.6.65
MAC00-FC41 connectors, rear plate layout
The set up of Baud-rate, Node-ID and terminator are selected in the same way as in the
MAC00-FC2 module.
Expansion MAC00-FC41 Hardware description:
The MAC00-FC41 offers IP67 on MAC050-141(only with extension -A009) and IP65 on
MAC400-4500 protection and M12 connectors which makes it ideal for automation ap-
plications where no additional protection is desired. The M12 connectors offer solid me-
chanical protection and are easy to unplug compared to the FC2 module which has cable
glands. The signals available are slightly restricted compared to the FC2 module since
only 4 I/O terminals are available. The I/O's connected to these 4 terminals must be se-
lected by a small dip-switch, see the drawing below the I/O table on the next page.
The connector layout:
"PWR" - Power input. M12 - 5-pin male connector
Signal
name
P+
P+
P-
CV
P-
* Note: P+ and P- is each available at 2 terminals. Make sure that both terminals are connected in order to split the supply
current in 2 terminals and thereby avoid an overload of the connector.
** Note: When using MAC400 to 4500 the P+ and CV terminal can maximum be supplied by 18-32VDC.
"BUS1" - CAN-open interface. M12 - 5-pin male connector
Signal
name
CAN_SHLD
CAN_V+
CAN_GND
CAN_H
CAN_L
JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
Expansion module MAC00-FC41 front plate
Description
Main supply +8-48VDC. Connect with pin 2 * / **
Main supply +8-48VDC. Connect with pin 1 * / **
Main supply ground. Connect with pin 5 *
Control voltage +8-48VDC / 18-32VDC **
Main supply ground. Connect with pin 3 *
Description
Shield for the CAN interface - internally connected to the
motor housing
Reserved for future purpose - do not connect
CAN interface ground
CAN interface. Positive signal line
CAN interface. Negative signal line
TT1283-01GB
Pin no.
1
2
3
4
5
Pin no.
1
2
3
4
5
PWR
Power
M12 - 5pin male
connector including:
P+, P- and secondary
supply (optional).
I/O
M12 - 8pin female
connector including:
RS232 Interface
Selectable I/O's such
as analogue input, O1,
O2, IN1, NL, PL.
JVL Cable
WI1000M1
Isola-
2
tion
F5T05N
group
Brown
1
White
1
Blue
1
Black
1
Grey
1
Cable:
WI1006-
Isola-
M12F5Sxx
tion
R
group
Bare
2
Red
2
Black
2
White
2
Blue
2
241