JVL MAC050 User Manual page 274

Integrated servo motors
Hide thumbs Also See for MAC050:
Table of Contents

Advertisement

5.8
Expansion Module MAC00-FP2/FP4
5.8.2
MAC00-FP2 and FP4 Address and Termination setup
Each unit connected to the Profibus must be set up with a unique address.
The illustration below shows how the address and termination can be set on the internal
dip switch. The dip switch is located on the internal circuit board.
Please notice that in newer modules
with firmware 3.01 or newer the address
can only be set by software
Dip 8 - Address set by software
Notes.
SW1 default setting: All switches set to "ON"
except 9+10 which are "OFF" which corresponds to
- Address is set by software / - Termination disabled
"Address set by software" (DIP8) means that
the profibus address will automatically be set
to the same value as the motor address
Important:
Please contact your JVL distributor if it is crucial to use the dip switch for address setup.
270
MAC00-FP2 and FP4 Dip switch settings
Dip 1-7 - Address setting
(address range 0-127)
Dip 9-10 - Line termination
Both set to ON =
Term. enabled
Both set to OFF =
Term. disabled
Cable glands
Profibus and I/O
connectors.
On newer modules with firmware 3.01 or 3.02 the dip switch 1 to 8 has
been disabled and the address can only be set in software by using for ex-
ample MacTalk.
JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
Mini dip-switch
OFF
ON
1
2
3
4
5
6
7
8
9
0
SW1
Dip switch location on the
MAC00-FP2 Expansion module
Dip Switch placed
on the rear side of the
module
Rear side of the MAC00-FP2 or FP4
expansion module
Basic MAC motor
housing
Internal circuit boards
TT0946GB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents