JVL MAC050 User Manual page 66

Integrated servo motors
Hide thumbs Also See for MAC050:
Table of Contents

Advertisement

2.12
Absolute Multiturn Encoder
2.12.2
How to setup the mechanical zero point (quick guide).
The tab "Absolute positioning" is visible in the MacTalk program when a motor with ab-
solute multiturn encoder is connected.
The functions showed below are used to adjust and monitor the actual encoder position.
Press
to store the modi?ed
encoder position
permanent
Physical position of the encoder.
This value is not possible to change and
must stay within +/-16.777.216 counts.
Procedure for adjusting the zero point:
1. Before mounting the motor in the application connect power to the motor.
2. Press the "Set offset = 0" button and move the motor until the "Encoder position"
shows close to 0. This is recommended to make sure that the full encoder working
range is available.
3. Mount the motor in the application and move it to the intended zero position.
4. Press the "Reset position" button to reset the "Actual position" (P_IST) and press the
"Save in Motor" button in order to store the zero point setting permanent in the mo-
tor.
62
Pressing the
"Save in
Motor
"
will reset the the absolute position (P_IST)
JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
botton
"Reset Position"
Select this tab when adjusting the encoder position
Usefull information exist here
(see also later in his chapter)
Make sure to clear any existing value
(if any) in the o?set register.
F
Only MACxxx-yy-
zzz
The Actual Position
of the motor.
TT1180
-01
GB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents