JVL MAC050 User Manual page 137

Integrated servo motors
Hide thumbs Also See for MAC050:
Table of Contents

Advertisement

4.3
4.3.3
Sampling Setup
In Sampling setup it is possible to select between recording of 4 or 8 register values.
Along with the channel count it is possible to choose different sample counts (512, 1024
and 2048 samples).
Selection of sample time impacts the total sample time along with number of channels,
samples. You can select 100uS or 1.3mS.
If extended recording time is preferred, you can so by activating Enable min/max/avg
sampling and select the desired Total sample time.
The entire scope setup is part of the general setup and will be saved along with all other
motor setup.
When saving scope data using the MacTalk® Scope Data Format (.scopeData), you
will be able to reload the recording back into MacTalk.
Reloaded scope data can still be saved as .CSV or .BMP, if needed.
JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
MacTalk Scope usage
TT1106-01GB