JVL MAC050 User Manual page 443

Integrated servo motors
Hide thumbs Also See for MAC050:
Table of Contents

Advertisement

6.12
Reg.
Firmware / MacRegIo
Nr.
Name
213
UART1_SETUP
(Continued)
214
EXTENC_BITS
215
INPUT_LEVELS
216
ANINP1
217
ANINP1_OFFSET
218
ANINP2
219
ANINP2_OFFSET
220
ANINP3
221
ANINP3_OFFSET
JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
Registers
MacTalk
Size /
Name
Access
Serial data
Na /
Word /
0
RW
Na /
Word /
(not present)
0
RW
Na /
Word /
(not present)
0
RW
Na /
Word /
(not present)
0
RW
Na /
Word /
(not present)
0
RW
Na /
Word /
(not present)
0
RW
Na /
Word /
(not present)
0
RW
Na /
Word /
(not present)
0
RW
Na /
Word /
(not present)
0
RW
Description
-
Bits [19:16]: Guard –time. Number of idle bit times between bytes
during transmission. These can be seen as additional
stop bits. Normally this value is set to zero, but with
some UARTs that have trouble synchronising when
long telegrams, this value can be set to non-zero.
Setting this value non-zero may help visually
separating bytes on an oscilloscope. Value can be
0..15
Bits [14:15]: Number of stop bits to use.
0=1, 1=1.5, 2=2 stop bits.
Bits [13:11]: Parity scheme. Modbus should use other Even or Odd
parity for maximum error checking. 0=Even, 1=Odd
Multi drop parity is not supported by Modbus, but a
non-standard multi-drop operation is supported, see bit
20 and 21.
Bits [10]:
Must always be zero.
Bits [9:8]:
Number of data bits in a byte. Modbus always uses 8
bits per byte. 3=8 data bits
Bits [7:4]:
Protocol to use – select 1 for Modbus.
The option to use Modbus address 254 ( instead of the
motor address) is intended for use with the JVL.
0=FastMac *, 1=Modbus ( motor address ), 2=Modbus
(address 254, 3=OMRON(subset) ).
Bits [3:0]:
Basic Baud rate in bits per second. 0=9600, 1=19200 *,
2=38400, 3=57600, 4=115200, 5=230400, 6=444444,
7=1000000, 8=2000000 baud.
-
Supports setup of signals used for label dispenser functionality with
the MAC00-B41 module.
-
Can be used to individually invert logical state of hardware inputs in
Reg106, DIGITAL_INPUTS
-
The input of hardware analogue input 1 (primary, available on all
modules).
This value can be read at all times, also if the analogue input
selected for motor control is selected to be one of ANINP2 or
ANINP3.
-
Offset for Reg216, ANNIP1
-
The input of hardware analogue input 2 (secondary, available on B41
and Ex41, more to come)
This value can be read at all times, also if the analogue input
selected for motor control is selected to be one of ANINP1 or
ANINP3.
-
Offset for Reg218, ANNIP2
-
The input of hardware analogue input 3 (tertiary, available on P4 and
P5 only, as a 4-20 mA current).
This value can be read at all times, also if the analogue input
selected for motor control is selected to be one of ANINP1 or
ANINP2.
-
Offset for Reg220, ANNIP3
Only MAC400 to 4500
TT15
52
-02GB
439