3.2
3.2.23
How to connect the power supply
The power supply for the control circuitry is connected through the expansion module
at the terminals called P+ and P- or directly at the internal power supply connector.
The power circuitry must be applied according to the illustration below.
Control power (+18-30VDC) must
be connected to the P+ and P- terminal
at the expansion module.
See the actual module used, for details
of connection.
Terminal descriptions:
L1
N
PE
PD
BO
CM
Important notes:
-
If 115VAC is used as supply voltage the MAC800 must be set up for this. See
115V supply voltage (MAC800/1200), page
-
Shielded cables is recommended.
3.2.24
MAC800/1200 Grounding
Make sure that the machine part on which the MAC800/1200 is mounted is properly
grounded to the main part (body) of the machine in order to avoid major ground/earth
current to flow through the motor and cause interference to other signal groups such as
interface cables.
102
Power Supply
MAC800/1200 supply connections
Remove the lit to access the internal supply terminals
115/230VAC input (phase). (The voltage range is set by solder jumper)
115/230VAC input (neutral). (The voltage range is set by solder jumper)
See
Using 115V supply voltage (MAC800/1200), page
Earth must be used with the DC-bus and the PD terminals.
Power dump output - see also
104.
Bus output (nom. 325VDC).
Common. Ground for the internal DC-bus.
CAUTION
- Risk of electric
shock. Disconnect all power and
wait 5 min. before servicing
JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
(MAC800/1200)
L1
N
PE (Earth)
PE (Earth)
PD
BO
CM
Main power, internal bus voltage and power
dump are accessible through these spring
contacts placed under the top lid.
Mains power must be 115 or 230VAC.