JVL MAC050 User Manual page 313

Integrated servo motors
Hide thumbs Also See for MAC050:
Table of Contents

Advertisement

5.10 Expansion module MAC00-P4/P5
"COM" - Communication connector - M12 - 5pin female connector.
Signal
name
RS232: TX
RS232: RX
IGND
RS485: A-
RS485: B+
"SLV" - Slave connector - M12 - 5pin male connector
Signal
name
RS485 A-
RS485 B+
CVI2
GND
IGND
*
The RS485 pins in "COM" and "SLV" is not for general use but only for master/slave
configuration.
JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
Description
RS232 interface. Transmit terminal
Leave open if unused.
RS232 interface. Receive terminal
Leave open if unused.
Ground intended to be used together with the
other signals in this connector,
RS485 Modbus *. Leave open if unused
RS485 Modbus *. Leave open if unused
Description
RS485 Modbus *. Positive terminal
RS485 Modbus *. Negative terminal
Supply output (optionally input) +18-32VDC
Hard-wired internally to CVI1.
Ground to be used with CVI2.
This ground is hard-wired internally to the main
power ground P-.
Multifunction I/O2 terminal B2+
Only MAC400-3000
JVL Ca-
ble
"RS232-
Pin
M12-1-5-
no.
5"
1
Brown
2
White
3
Blue
4
Black
5
Grey
JVL Ca-
ble
"WI1005-
Pin
M12F5TF
no.
5T03P"
1
1
4
4
2
2
3
3
5
Screen wire
Isola-
tion
group
(See
note)
4
4
4
4
4
Isola-
tion
group
(see
note)
4
4
0
0
4
309