JVL MAC050 User Manual page 385

Integrated servo motors
Hide thumbs Also See for MAC050:
Table of Contents

Advertisement

6.6
6.6.3
Precautions when installing IPx5/x6/x7 motors
When installing MAC motors with a higher ingress protection (IPx5/x6/x7) a few rules
must be respected in order to assure no ingress over time.
!
Rule 1 - Mounting the expansion module (MAC00-xxx)
All the expansion modules are IP67 rated but under the condition that its mounted cor-
rectly in the motor so the surface of the module is in same level as the surrounding motor
surface.
The 2 pcs. M2.5 hexagon screws in the module must also be tightened with 0.8 to 1.0
Nm. Use a torque screw driver to make sure the torque is ok.
Also make sure to use protective caps on unused connectors.
Rule 2 - Connectors
Make sure to tighten all connectors with a proper high torque to make sure that no mois-
ture/liquids can find a way inside the connector.
All circular connectors at motors and modules including cables with matching connectors
offered by JVL is guaranteed to be IP67 or higher but under the condition that they are
tightened with a proper high torque.
Make sure to use protective caps at unused connectors. Also make sure that the protec-
tive caps a tightened properly.
JVL A/S - User Manual - Integrated Servo Motors MAC050 - 4500
Installation instructions
Please notice:
The MAC products are not covered by the warranty if the following rules/
guidance is not fully followed.
Use protective caps at unused connectors
Remember to fasten these properly.
Grease 360 degree around the edge
Tightend these 2 screws
with 0.8 to 1.0 Nm
Mandatory:
Add a bit of synthetic grease
360 degree around the edge of
the module before mounting
TT1285-01GB
381