1.2 Catalog Code and Nameplate Check
No.
1
GA800 Series
2
Region code
• U: Americas
3
Input power supply voltage
• 2: Three-Phase AC 200 V Class
• 4: Three-Phase AC 400 V Class
• T: 6-Phase/12-Pulse 400 V Class
Note:
The software version for 6-Phase/12-Pulse drives is PRG: 09015 and later. The "PRG" column on the nameplate on the right side of the drive identifies the software
version. You can also use U1-25 [SoftwareNumber Flashr] to identify the software version.
4
Rated output current
Note:
Refer to the tables for the rated output current by model.
5
EMC noise filter
• Three-Phase AC 200 V Class and 400 V Class
– A: No internal EMC filter
– B: Internal category C3 EMC filter
• 6-Phase/12-Pulse 400 V Class
– A: No internal EMC filter
6
Enclosure protection design
• Three-Phase AC 200 V Class and 400 V Class
– B: IP20/UL Open Type
– W: IP55/UL Type 12 Heatsink External Mounting
• 6-Phase/12-Pulse 400 V Class
– A: IP00/UL Open Type
– W: IP55/UL Type 12 Heatsink External Mounting
7
Environmental specification
A: Standard
M: Humidity-resistant and dust-resistant
Rated Output Current
Table
1.2,
Table
1.3, and
Note:
• These output current values are applicable for drives that operate at standard specifications.
• Derate the output current in applications that:
–Increase the carrier frequency
–Have high ambient temperature
–Install drives side-by-side.
• Use C6-01 [Normal / Heavy Duty Selection] to select Normal Duty rating (ND) or Heavy Duty rating (HD).
Model
2004
2006
2008
2010
2012
2018
26
Table 1.1 Catalog Code Details
Table 1.4
give the rated output current values.
Table 1.2 Rated Output Current: Three-Phase 200 V Class
Heavy Duty Rating (HD)
[C6-01 = 0]
Maximum Applicable Motor
Output
kW (HP)
0.55 (0.75)
0.75 (1)
1.1 (1.5)
1.5 (2)
2.2 (3)
3 (4)
Description
Maximum Applicable Motor
Rated Output Current
A
3.5
5
6.9
8
11
14
YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Normal Duty Rating (ND)
[C6-01 = 1]
(Default)
Rated Output Current
Output
kW (HP)
0.75 (1)
1.1 (1.5)
1.5 (2)
2.2 (3)
3 (4)
3.7 (5)
A
4.2
6
8
9.6
12.2
17.5