YASKAWA HV600 Technical Reference page 677

Ac drive bypass for hvac fan and pump applications
Hide thumbs Also See for HV600:
Table of Contents

Advertisement

No.
Name
(Hex.)
U3-40
Fault 7 MMDD
(301E)
U3-41
Fault 7 HHMM
(301F)
U3-42
Fault 8 YYYY
(3020)
U3-43
Fault 8 MMDD
(3021)
U3-44
Fault 8 HHMM
(3022)
U3-45
Fault 9 YYYY
(3023)
U3-46
Fault 9 MMDD
(3024)
U3-47
Fault 9 HHMM
(3025)
U3-48
Fault 10 YYYY
(3026)
U3-49
Fault 10 MMDD
(3027)
U3-50
Fault 10 HHMM
(3028)
U4: Maintenance Monitors
No.
Name
(Hex.)
U4-01
Cumulative Ope Time
(004C)
U4-02
Num of Run Commands
(0075)
U4-03
Cooling Fan Ope Time
(0067)
U4-04
Cool Fan Maintenance
(007E)
YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
Shows the month and day when the seventh most recent fault occurred.
Shows the time when the seventh most recent fault occurred.
Shows the year when the eighth most recent fault occurred.
Shows the month and day when the eighth most recent fault occurred.
Shows the time when the eighth most recent fault occurred.
Shows the year when the ninth most recent fault occurred.
Shows the month and day when the ninth most recent fault occurred.
Shows the time when the ninth most recent fault occurred.
Shows the year when the tenth most recent fault occurred.
Shows the month and day when the tenth most recent fault occurred.
Shows the time when the tenth most recent fault occurred.
Shows the cumulative operation time of the drive.
Use parameter o4-01 [Elapsed Operating Time Setting] to reset this monitor. Use parameter o4-02
[Elapsed Operating Time Selection] to select the cumulative operation times from:
• The time from when the drive is energized until it is de-energized.
• The time at which the Run command is turned ON.
The maximum value that the monitor will show is 99999. After this value is more than 99999, the
drive automatically resets it and starts to count from 0 again.
Unit: 1 h
Note:
The MEMOBUS/Modbus communication data is shown in 10 h units. Use register 0099H for
data in 1 h units.
Shows how many times that the drive has received a Run command.
Use parameter o4-13 [RUN Command Counter @ Initialize] to reset this monitor. The maximum
value that the monitor will show is 65535. After this value is more than 65535, the drive
automatically resets it and starts to count from 0 again.
Unit: 1
Shows the cumulative operation time of the cooling fans.
Use parameter o4-03 [Fan Operation Time Setting] to reset this monitor. The maximum value that
the monitor will show is 99999. After this value is more than 99999, the drive automatically resets it
and starts to count from 0 again.
Unit: 1 h
Note:
The MEMOBUS/Modbus communication data is shown in 10 h units. Use register 009BH for
data in 1 h units.
Shows the cumulative operation time of the cooling fans as a percentage of the replacement life of
the cooling fans.
Use parameter o4-03 [Fan Operation Time Setting] to reset this monitor.
Unit: 1%
Note:
Replace the cooling fans when this monitor is 90%.
Description
Description
9.18 U: Monitors
MFAO Signal Level
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
No signal output available
MFAO Signal Level
10 V: 99999 h
10 V: 65535 times
10 V: 99999 h
10 V: 100%
9
677