YASKAWA HV600 Technical Reference page 615

Ac drive bypass for hvac fan and pump applications
Hide thumbs Also See for HV600:
Table of Contents

Advertisement

9.10
H: Terminal Functions
H1: Digital Inputs
No.
Name
(Hex.)
H1-01
Terminal S1 Function
Selection
(0438)
H1-02
Terminal S2 Function
Selection
(0439)
H1-03
Terminal S3 Function
Selection
(0400)
H1-04
Terminal S4 Function
Selection
(0401)
H1-05
Terminal S5 Function
Selection
(0402)
H1-06
Terminal S6 Function
Selection
(0403)
H1-07
Terminal S7 Function
Selection
(0404)
H1-61
Terminal S1 On-Delay
Time
(39E1)
RUN
H1-62
Terminal S2 On-Delay
Time
(39E2)
RUN
H1-63
Terminal S3 On-Delay
Time
(39E3)
RUN
H1-64
Terminal S4 On-Delay
Time
(39E4)
RUN
H1-65
Terminal S5 On-Delay
Time
(39E5)
RUN
H1-66
Terminal S6 On-Delay
Time
(39E6)
RUN
H1-67
Terminal S7 On-Delay
Time
(39E7)
RUN
H1-71
Terminal S1 Off-Delay
Time
(39EB)
RUN
H1-72
Terminal S2 Off-Delay
Time
(39EC)
RUN
H1-73
Terminal S3 Off-Delay
Time
(39ED)
RUN
H1-74
Terminal S4 Off-Delay
Time
(39EE)
RUN
H1-75
Terminal S5 Off-Delay
Time
(39EF)
RUN
YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
Description
Sets the function for MFDI terminal S1.
Sets the function for MFDI terminal S2.
Sets the function for MFDI terminal S3.
Sets the function for MFDI terminal S4.
Sets the function for MFDI terminal S5.
Sets the function for MFDI terminal S6.
Sets the function for MFDI terminal S7.
Sets the length of time necessary for Terminal S1 to be closed before the drive does the
programmed function.
Sets the length of time necessary for Terminal S2 to be closed before the drive does the
programmed function.
Sets the length of time necessary for Terminal S3 to be closed before the drive does the
programmed function.
Sets the length of time necessary for Terminal S4 to be closed before the drive does the
programmed function.
Sets the length of time necessary for Terminal S5 to be closed before the drive does the
programmed function.
Sets the length of time necessary for Terminal S6 to be closed before the drive does the
programmed function.
Sets the length of time necessary for Terminal S7 to be closed before the drive does the
programmed function.
Sets the length of time necessary for Terminal S1 to be open before the drive removes the
programmed function.
Sets the length of time necessary for Terminal S2 to be open before the drive removes the
programmed function.
Sets the length of time necessary for Terminal S3 to be open before the drive removes the
programmed function.
Sets the length of time necessary for Terminal S4 to be open before the drive removes the
programmed function.
Sets the length of time necessary for Terminal S5 to be open before the drive removes the
programmed function.
9.10 H: Terminal Functions
Default
Ref.
(Range)
40
261
(3 to 1A8)
F
261
(3 to 1A8)
24
261
(3 to 1A8)
14
261
(3 to 1A8)
3
261
(3 to 1A8)
4
261
(3 to 1A8)
6
261
(3 to 1A8)
0.00 s
262
(0.00 - 300.00 s)
0.00 s
262
(0.00 - 300.00 s)
0.00 s
263
(0.00 - 300.00 s)
0.00 s
263
(0.00 - 300.00 s)
0.00 s
263
(0.00 - 300.00 s)
0.00 s
263
(0.00 - 300.00 s)
0.00 s
263
(0.00 - 300.00 s)
0.00 s
263
(0.00 - 300.00 s)
0.00 s
263
(0.00 - 300.00 s)
0.00 s
264
(0.00 - 300.00 s)
0.00 s
264
(0.00 - 300.00 s)
0.00 s
264
(0.00 - 300.00 s)
9
615