YASKAWA HV600 Technical Reference page 612

Ac drive bypass for hvac fan and pump applications
Hide thumbs Also See for HV600:
Table of Contents

Advertisement

9.9 F: Options
No.
Name
(Hex.)
F7-05
Subnet Mask 1
(03E9)
F7-06
Subnet Mask 2
(03EA)
F7-07
Subnet Mask 3
(03EB)
F7-08
Subnet Mask 4
(03EC)
F7-09
Gateway Address 1
(03ED)
F7-10
Gateway Address 2
(03EE)
F7-11
Gateway Address 3
(03EF)
F7-12
Gateway Address 4
(03F0)
F7-13
Address Mode at Startup
(03F1)
F7-14
Duplex Mode Selection
(03F2)
F7-15
Communication Speed
Selection
(03F3)
F7-16
Timeout Value
(03F4)
F7-17
EtherNet/IP Speed
Scaling Factor
(03F5)
F7-18
EtherNet/IP Current Scale
Factor
(03F6)
F7-19
EtherNet/IP Torque Scale
Factor
(03F7)
612
Sets the first octet of the subnet mask of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Sets the second octet of the subnet mask of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Sets the third octet of the subnet mask of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Sets the fourth octet of the subnet mask of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Sets the first octet of the gateway address of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Sets the second octet of the gateway address of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Sets the third octet of the gateway address of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Sets the fourth octet of the gateway address of the connected network.
Note:
Set this parameter when F7-13 = 0 [Address Mode at Startup = Static].
Sets the method to set option card IP addresses.
0 : Static
1 : BOOTP
2 : DHCP
Note:
• The following setting values are available when using the PROFINET
communication option card (SI-EP3).
–0: Static
–2: DHCP
• When F7-13 = 0, set parameters F7-01 to F7-12 [IP Address 1 to Gateway Address
4] to set the IP Address. Be sure to set a different IP address for each drive on the
network.
Sets the duplex mode setting method.
0 : Half/Half
1 : Auto/Auto
2 : Full/Full
3 : Half/Auto
4 : Half/Full
5 : Auto/Half
6 : Auto/Full
7 : Full/Half
8 : Full/Auto
Sets the communications speed.
10 : 10/10 Mbps
100 : 100/100 Mbps
101 : 10/100 Mbps
102 : 100/10 Mbps
Sets the detection time for a communications timeout.
Note:
Set this parameter to 0.0 to disable the connection timeout function.
Sets the scaling factor for the speed monitor in the EtherNet/IP Class ID 2AH Object.
Sets the scaling factor for the output current monitor in the EtherNet/IP Class ID 2AH
Object.
Sets the scaling factor for the torque monitor in the EtherNet/IP Class ID 2AH Object.
Description
YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
Default
Ref.
(Range)
255
256
(0 - 255)
255
256
(0 - 255)
255
256
(0 - 255)
0
257
(0 - 255)
192
257
(0 - 255)
168
257
(0 - 255)
1
257
(0 - 255)
1
257
(0 - 255)
2
257
(0 - 2)
1
258
(0 - 8)
10
258
(10, 100 - 102)
0.0 s
258
(0.0 - 30.0 s)
0
259
(-15 - +15)
0
259
(-15 - +15)
0
259
(-15 - +15)

Advertisement

Table of Contents
loading

Table of Contents