240 V Enclosed Wire Gauges and Torques
Model
H6BP
Current Rating
Amps
A002
20
A003
20
A004
20
A006
20
A009
20
A015
20
A022
45
A028
63
A042
100
A054
100
A068
100
A080
115
A104
175
A130
250
A154
250
A192
250
A248
400
Motor Wiring
Standard Motor
Terminal Block TB1
Model
H6BP
Tightening
AWG,
Torque
kcmil
(in lb)
14-10, 8, 6-
A002
14-2
32
A003
14-10, 8, 6-
14-2
32
A004
14-10, 8, 6-
14-2
32
A006
14-10, 8, 6-
14-2
32
14-10, 8, 6-
A009
14-2
32
A015
14-10, 8, 6-
14-2
32
A022
14-10, 8, 6-
14-2
32
A028
14-10, 8, 6-
14-2
32
A042
14-10, 8, 6-
14-2
32
A054
14-10, 8, 6-
14-2
32
YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
Table 3.7 Input Wiring
Standard Non-Fused
Input Disconnect Switch S1
Tightening Torque
AWG, kcmil
14-8
14-8
14-8
14-8
14-8
14-8
10, 8, or (6-2)
35, 40, or 50
10, 8, or (6-2)
35, 40, or 50
8-2/0
8-2/0
8-2/0
8-2/0
4-4/0
3/0-350 kcmil
3/0-350 kcmil
3/0-350 kcmil
(1-2) x (2/0-500 kcmil)
Table 3.8 Output and Control Wiring
Ground Wiring
A1
Terminal Blocks
Tightening
TB1, TB3-TB6
AWG,
Torque
kcmil
(in lb)
Tightening
AWG,
kcmil
35, 40, 45,
24-16
4, or 2
or 50
35, 40, 45,
24-16
4, or 2
or 50
35, 40, 45,
24-16
4, or 2
or 50
35, 40, 45,
24-16
4, or 2
or 50
35, 40, 45,
24-16
4, or 2
or 50
35, 40, 45,
24-16
4, or 2
or 50
35, 40, 45,
24-16
4, or 2
or 50
35, 40, 45,
24-16
4, or 2
or 50
35, 40, 45,
24-16
4, or 2
or 50
35, 40, 45,
24-16
4, or 2
or 50
Current Rating
(in lb)
Amps
20
15
20
15
20
15
20
20
20
25
20
35
50
70
200
100
200
125
200
150
200
150
225
150
225
250
225
250
225
400
(1-2) x 442
600
Control Wiring
A1
Terminal Block
TB2 (FE)
Tightening
AWG,
Torque
Torque
kcmil
(in lb)
(in lb)
8.85 to
*1
4.4 to 5.3
24-18
10.62
8.85 to
*1
4.4 to 5.3
24-18
10.62
8.85 to
*1
4.4 to 5.3
24-18
10.62
8.85 to
*1
4.4 to 5.3
24-18
10.62
8.85 to
*1
4.4 to 5.3
24-18
10.62
8.85 to
*1
4.4 to 5.3
24-18
10.62
8.85 to
*1
4.4 to 5.3
24-18
10.62
8.85 to
*1
4.4 to 5.3
24-18
10.62
8.85 to
*1
4.4 to 5.3
24-18
10.62
8.85 to
*1
4.4 to 5.3
24-18
10.62
3.3 Main Circuit Wiring
With Option PM
Circuit Breaker CB1
Tightening Torque
AWG, kcmil
(in lb)
14-10 or 8-3/0
50 or 120
14-10 or 8-3/0
50 or 120
14-10 or 8-3/0
50 or 120
14-10 or 8-3/0
50 or 120
14-10 or 8-3/0
50 or 120
14-10 or 8-3/0
50 or 120
14-10 or 8-3/0
50 or 120
14-10 or 8-3/0
50 or 120
14-10 or 8-3/0
50 or 120
14-10 or 8-3/0
50 or 120
14-10 or 8-3/0
50 or 120
14-10 or 8-3/0
50 or 120
14-10 or 8-3/0
50 or 120
4-4/0
225
3/0-350
225
(1-2) x (2/0-500 kcmil)
(1-2) x 442
(1-2) x (2/0-500 kcmil)
(1-2) x 442
A2
Panel
Terminal Blocks
Terminal Block
TB1-TB4 and TB6
TB4
Tightening
Tightening
AWG,
AWG,
Torque
kcmil
kcmil
(in lb)
26-14
4
26-10
26-14
4
26-10
26-14
4
26-10
26-14
4
26-10
26-14
4
26-10
26-14
4
26-10
26-14
4
26-10
26-14
4
26-10
26-14
4
26-10
26-14
4
26-10
3
Torque
(in lb)
5.3 to 7.1
5.3 to 7.1
5.3 to 7.1
5.3 to 7.1
5.3 to 7.1
5.3 to 7.1
5.3 to 7.1
5.3 to 7.1
5.3 to 7.1
5.3 to 7.1
85