YASKAWA HV600 Technical Reference page 47

Ac drive bypass for hvac fan and pump applications
Hide thumbs Also See for HV600:
Table of Contents

Advertisement

2.
Loosen the front cover screw.
3.
Push on the tabs in the sides of the front cover then pull the front cover forward to remove it from the drive.
Reattach the Front Cover
1.
Wire the drive and other peripheral devices.
2.
Reverse the steps to reattach the cover.
Note:
• Make sure that you did not pinch wires or signal lines between the front cover and the drive before you reattach the cover.
• Make sure that the tabs on the sides of the front cover correctly click into the hook.
• Tighten the screws to a tightening torque of 0.98 N∙m to 1.33 N∙m (8.67 in∙lb to 11.77 in∙lb).
YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
Figure 2.14 Loosen the Front Cover Screw
Figure 2.15 Remove the Front Cover
Figure 2.16 Reattach the Front Cover