9.13 o: Keypad-Related Settings
o2: Keypad Operation
No.
Name
(Hex.)
o2-02
OFF Key Function
Selection
(0506)
o2-03
User Parameter Default
Value
(0507)
o2-04
Drive Model (KVA)
Selection
(0508)
o2-05
Home Mode Freq Ref
Entry Mode
(0509)
o2-06
Keypad Disconnect
Detection
(050A)
o2-09
Reserved
(050D)
o2-19
Parameter Write during
Uv
(061F)
o2-24
LED Light Function
Selection
(11FE)
o2-27
bCE Detection Selection
(1565)
o3: Copy Keypad Function
No.
Name
(Hex.)
o3-01
Copy Keypad Function
Selection
(0515)
o3-02
Copy Allowed Selection
(0516)
644
Sets the function to use
on the keypad to stop the drive when the Run command
source for the drive is REMOTE (external) and not assigned to the keypad.
0 : Disabled
1 : Enabled
Sets the function to keep the settings of changed parameters as user parameter defaults to
use during initialization.
0 : No change
1 : Set defaults
2 : Clear all
Sets the Drive Model code. Set this parameter after you replace the control board.
Sets the function that makes it necessary to push
frequency reference value while in Drive Mode.
0 : ENTER Key Required
1 : Immediate / MOP-style
Sets the function that stops the drive if you disconnect the keypad connection cable from
the drive or if you damage the cable while the keypad is the Run command source.
0 : Disabled
1 : Enabled
-
Enables and disables the function to change parameter settings during a Uv [DC Bus
Undervoltage] condition.
0 : Disabled
1 : Enabled
Sets the function to show the LED status rings and keypad LED lamps.
Note:
When you use A1-03 [Initialize Parameters] to initialize the drive, the drive will not
reset this parameter.
0 : Enable Status Ring & Keypad LED
1 : LED Status Ring Disable
2 : Keypad LED Light Disable
Sets drive operation if the Bluetooth device is disconnected when you operate the drive in
Bluetooth Mode.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : No Alarm Display
Sets the function that saves and copies drive parameters to a different drive with the
keypad.
0 : Copy Select
1 : Backup (drive → keypad)
2 : Restore (keypad → drive)
3 : Verify (check for mismatch)
4 : Erase (backup data of keypad)
Sets the copy function when o3-01 = 1 [Copy Keypad Function Selection = Backup (drive
→ keypad)].
0 : Disabled
1 : Enabled
Description
to use the keypad to change the
Description
YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
Default
Ref.
(Range)
1
362
(0, 1)
0
363
(0 - 2)
Determined by the drive
363
(-)
0
364
(0, 1)
1
364
(0, 1)
-
364
0
364
(0, 1)
0
365
(0 - 2)
3
365
(0 - 4)
Default
Ref.
(Range)
0
365
(0 - 4)
0
365