YASKAWA HV600 Technical Reference page 363

Ac drive bypass for hvac fan and pump applications
Hide thumbs Also See for HV600:
Table of Contents

Advertisement

To start the drive again after you push
o2-03: User Parameter Default Value
No.
Name
(Hex.)
o2-03
User Parameter Default
Value
(0507)
When you set o2-03 = 1 [Set defaults], the drive saves changed parameter settings as user parameter setting values in
a part of the memory that is isolated from drive parameters.
When you set A1-03 = 1110 [Initialize Parameters = User Initialization] to initialize the drive, the drive resets the
internal parameter setting values to those user parameter setting values.
0 : No change
1 : Set defaults
Saves changed parameter setting values as user default settings.
Set o2-03 = 1 then push
automatically resets to 0.
2 : Clear all
Deletes all of the saved user parameter setting values.
Set o2-03 = 2 then push
you delete the user parameter setting values, you cannot set A1-03 = 1110 to initialize parameters.
o2-04: Drive Model (KVA) Selection
No.
Name
(Hex.)
o2-04
Drive Model (KVA)
Selection
(0508)
NOTICE: Set o2-04 [Drive Model Selection] correctly. If you set this parameter incorrectly, it will decrease drive performance, cause
the protection function to operate incorrectly, and cause damage to the drive.
Note:
When the setting value of o2-04 changes, related parameter setting values also change. Refer to
688
for more information.
These tables list the relation between o2-04 setting values and drive models.
o2-04 Setting
65
67
68
6A
6B
6D
6E
6F
70
72
73
74
75
YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
to stop operation, turn the external Run command OFF and ON again.
Sets the function to keep the settings of changed parameters as user parameter defaults to use during
initialization.
to save the user parameter setting values. After the drive saves the setting value, o2-03
to clear the user parameter setting values. The drive will automatically reset o2-03 to 0. If
Sets the Drive Model code. Set this parameter after you replace the control board.
Drive Model
2011
2017
2024
2031
2046
2059
2075
2088
2114
2143
2169
2211
2273
5.10 o: Keypad-Related Settings
Description
Description
Defaults by Bypass and Drive Model on page
o2-04 Setting
95
97
99
9A
9B
9D
9E
9F
A0
A2
A3
A4
A5
Default
(Range)
0
(0 - 2)
Default
(Range)
Determined by the drive
(-)
Drive Model
4005
5
4008
4011
4014
4021
4027
4034
4040
4052
4065
4077
4096
4124
363