YASKAWA HV600 Technical Reference page 632

Ac drive bypass for hvac fan and pump applications
Hide thumbs Also See for HV600:
Table of Contents

Advertisement

9.10 H: Terminal Functions
No.
Name
(Hex.)
H7-03
Virtual Multi-Function
Input 3
(1187)
Expert
H7-04
Virtual Multi-Function
Input 4
(1188)
Expert
H7-10
Virtual Multi-Function
Output 1
(11A4)
Expert
H7-11
Virtual Output 1 Delay
Time
(11A5)
Expert
H7-12
Virtual Multi-Function
Output 2
(11A6)
Expert
H7-13
Virtual Output 2 Delay
Time
(11A7)
Expert
H7-14
Virtual Multi-Function
Output 3
(11A8)
Expert
H7-15
Virtual Output 3 Delay
Time
(11A9)
Expert
H7-16
Virtual Multi-Function
Output 4
(11AA)
Expert
H7-17
Virtual Output 4 Delay
Time
(11AB)
Expert
H7-30
Virtual Analog Input
Selection
(1177)
Expert
H7-31
Virtual Analog Input
Gain
(1178)
RUN
Expert
H7-32
Virtual Analog Input Bias Sets the virtual analog input bias.
(1179)
RUN
Expert
H7-40
Virtual Analog Out
Signal Select
(1163)
H7-41
Virtual Analog Output
Function
(1164)
H7-42
Virtual Analog Output
FilterTime
(1165)
632
Sets the function that enters the virtual input set in H7-14 [Virtual Multi-Function Output
3].
Note:
Settings 1B [Programming Lockout] and 11B [!Programming Lockout] are not
available.
Sets the function that enters the virtual input set in H7-16 [Virtual Multi-Function Output
4].
Note:
Settings 1B [Programming Lockout] and 11B [!Programming Lockout] are not
available.
Sets the function for virtual digital output 1.
Sets the minimum ON time for virtual digital output 1.
Sets the function for virtual digital output 2.
Sets the minimum ON time for virtual digital output 2.
Sets the function for virtual digital output 3.
Sets the minimum ON time for virtual digital output 3.
Sets the function for virtual digital output 4.
Sets the minimum ON time for virtual digital output 4.
Sets the virtual analog input function.
Sets the virtual analog input gain.
Sets the signal level of the virtual analog output.
0 : 0 to 100% (Absolute Value)
1 : -100 to 100%
2 : 0 to 100% (Lower Limit at 0)
Sets the monitor to be output from the virtual analog output.
Set the x-xx part of the Ux-xx [Monitor]. For example, set H7-41 = 102 to monitor U1-02
[Output Frequency].
Sets the time constant for a primary filter of the virtual analog output.
Description
YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
Default
Ref.
(Range)
F
313
(1 - 1B8)
F
314
(1 - 1B8)
F
314
(0 - 1A7)
0.1 s
314
(0.0 - 25.0 s)
F
314
(0 - 1A7)
0.1 s
314
(0.0 - 25.0 s)
F
314
(0 - 1A7)
0.1 s
314
(0.0 - 25.0 s)
F
315
(0 - 1A7)
0.1 s
315
(0.0 - 25.0 s)
F
315
(0 - 31)
100.0%
315
(-999.9 - 999.9%)
0.0%
315
(-999.9 - 999.9%)
0
315
(0 - 2)
102
315
(0 - 999)
0.00 s
316
(0.00 - 2.00 s)