Parameter Descriptions
3.15 Parameters: 15-** Drive Information
3.15.1 15-0* Operating Data
15-00 Operating hours
3
3
Range:
0 h
*
2147483647 h]
15-01 Running Hours
Range:
0 h
*
2147483647 h]
15-02 kWh Counter
Range:
0 kWh
*
2147483647
kWh]
15-03 Power Up's
Range:
0
*
2147483647 ]
15-04 Over Temp's
Range:
0
*
15-05 Over Volt's
Range:
0
*
15-06 Reset kWh Counter
Option:
[0]
Do not reset
*
[1]
Reset counter
15-07 Reset Running Hours Counter
Option:
[0]
Do not reset
*
242
Function:
[0 -
View how many hours the
frequency converter has run. The
value is saved when the frequency
converter is turned off.
Function:
[0 -
View how many hours the motor
has run. Reset the counter in
parameter 15-07 Reset Running
Hours Counter. The value is saved
when the frequency converter is
turned off.
Function:
[0 -
Register the power consumption of
the motor as an average value over
1 hour. Reset the counter in
parameter 15-06 Reset kWh Counter.
Function:
[0 -
View the number of times the
frequency converter has been
powered up.
Function:
[0 - 65535 ]
View the number of frequency
converter temperature faults.
Function:
[0 - 65535 ]
View the number of frequency
converter overvoltages.
Function:
No reset of the kWh counter is
required.
Press [OK] to reset the kWh counter
to 0 (see parameter 15-02 kWh
Counter).
Function:
Danfoss A/S © 10/2019 All rights reserved.
®
VLT
AutomationDrive FC 301/302
15-07 Reset Running Hours Counter
Option:
[1]
3.15.2 15-1* Data Log Settings
The data log enables continuous logging of up to 4 data
sources (parameter 15-10 Logging Source) at individual rates
(parameter 15-11 Logging Interval). A trigger event
(parameter 15-12 Trigger Event) and window
(parameter 15-14 Samples Before Trigger) are used to start
and stop the logging conditionally.
15-10 Logging Source
Option:
[0]
*
[15]
[1397]
[1398]
[1399]
[1472]
[1473]
[1474]
[1600]
[1601]
[1602]
[1603]
[1606]
[1607]
[1608]
[1610]
[1611]
[1612]
[1613]
[1614]
Function:
Reset counter
To reset the running hours counter
to 0, select [1] Reset and press [OK]
(see parameter 15-01 Running
Hours). This parameter cannot be
selected via the serial port, RS485.
Select [0] Do not reset if no reset of
the running-hours counter is
required.
Function:
Select which variables are to be
logged.
None
Readout:
actual setup
Alert Alarm
Word
Alert Warning
Word
Alert Status
Word
Legacy Alarm
Word
Legacy
Warning Word
Leg. Ext.
Status Word
Control Word
Reference
[Unit]
Reference %
Status Word
Actual Position
Target Position This option is only available for
software version 48.XX
Position Error
This option is only available for
software version 48.XX
Power [kW]
Power [hp]
Motor Voltage
Frequency
Motor current
M0013101