Danfoss VLT AutomationDrive FC 301 Programming Manual page 211

Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

Parameter Descriptions
13-10 Comparator Operand
Option:
Function:
Position and
parameter 3-07 Maximum Position.
NOTICE
[226]
Touch on
Target
This option is available only
with software version 48.20
and newer.
Target position is reached in touch
probe position mode.
NOTICE
[227]
Touch
Activated
This option is available only
with software version 48.20
and newer.
Touch probe positioning active. The
frequency converter monitors the
touch probe sensor input.
[249]
Therm. Sensor
Temp.
13-11 Comparator Operator
Option:
Function:
Select the operator to be used in
the comparison. This is an array
parameter containing comparator
operators 0–5.
[0]
<
The result of the evaluation is true
when the variable selected in
parameter 13-10 Comparator
Operand is smaller than the fixed
value in
parameter 13-12 Comparator Value.
The result is false if the variable
selected in
parameter 13-10 Comparator
Operand is greater than the fixed
value in
parameter 13-12 Comparator Value.
[1]
≈ (equal)
The result of the evaluation is true
when the variable selected in
parameter 13-10 Comparator
Operand is approximately equal to
the fixed value in
parameter 13-12 Comparator Value.
[2]
>
Inverse logic of option [0] <.
[5]
TRUE longer
than..
[6]
FALSE longer
than..
[7]
TRUE shorter
than..
M0013101
Programming Guide
13-11 Comparator Operator
Option:
[8]
13-12 Comparator Value
Array [6]
Range:
Size
related
*
3.13.3 RS Flip Flops
The reset/set flip flops hold the signal until set/reset.
Illustration 3.55 Reset/Set Flip Flops
2 parameters are used, and the output can be used in the
logic rules and as events.
Illustration 3.56 Flip Flop Outputs
The 2 operators can be selected from a long list. As a
special case, the same digital input can be used as both
set and reset, making it possible to use the same digital
input as start/stop. The following settings can be used to
set up the same digital input (for example, DI32) as start/
stop.
Parameter
Parameter 13-00 SL Controller
Mode
Parameter 13-01 Start Event [0] True
Parameter 13-02 Stop Event [0] False
Parameter 13-40 Logic Rule
Boolean 1 [0]
Parameter 13-42 Logic Rule
Boolean 2 [0]
Danfoss A/S © 10/2019 All rights reserved.
Function:
FALSE shorter
than..
Function:
[ -100000.000
Enter the trigger level for the
- 100000 ]
variable that is monitored by this
comparator. This is an array
parameter containing comparator
values 0–5.
Par. 13-15
RS-FF Operand S
Par. 13-16
RS-FF Operand R
S
R
Flip Flop Output
Setting
Notes
On
[37] Digital
Input DI32
[2] Running –
3
3
209

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt automationdrive fc 302

Table of Contents