Parameter Descriptions
0-67 Bus Password Access
Range:
Function:
0
[0 - 9999 ]
Use this parameter to unlock the
*
frequency converter via fieldbus or
MCT 10 Set-up Software.
0-68 Safety Parameters Password
Range:
Function:
300
[0 - 9999 ]
Enter the password for the safety
*
parameters access. If
parameter 0-69 Password Protection
of Safety Parameters is set to [0]
Disabled, this parameter is ignored.
0-69 Password Protection of Safety Parameters
Option:
Function:
[0]
Disabled
*
[1]
Enabled
0-70 Date and Time
Range:
Function:
Size
[ 0 - 0 ]
Sets the date and time of the
related
internal clock. The format to be
*
used is set in parameter 0-71 Date
Format and parameter 0-72 Time
Format.
When using the VLT
Clock MCB 117 option, the time is
synchronized at 15:00 every day.
0-71 Date Format
Option:
Function:
[0]
YYYY-MM-DD
[1]
DD-MM-YYYY
[2]
MM/DD/YYYY
0-72 Time Format
Option:
Function:
[0]
24 h
[1]
12 h
0-73 Time Zone Offset
Range:
Function:
0 min
[-780 - 780
Enter the time zone offset relative
*
min]
to UTC. This parameter is required
for the automatic daylight saving
time adjustment.
0-74 DST/Summertime
Option:
Function:
Select how to handle daylight
saving time/summer time. For
manual setting of DST/summer
time, enter the start date and end
date in parameter 0-76 DST/
M0013101
Programming Guide
0-74 DST/Summertime
Option:
[0]
*
[2]
0-76 DST/Summertime Start
Range:
Size
related
*
0-77 DST/Summertime End
Range:
Size
related
*
0-79 Clock Fault
Option:
®
Real-time
[0]
[1]
0-81 Working Days
Array [7]
Array with 7 elements [0]–[6] shown below the parameter
number in the display. Press [OK] and step between elements
with [
Option:
[0]
[1]
Danfoss A/S © 10/2019 All rights reserved.
Function:
Summertime Start and
parameter 0-77 DST/Summertime
End.
Off
Manual
Function:
[ 0 - 0 ]
Sets the date and time when DST/
summer time starts. The date is
programmed in the format selected
in parameter 0-71 Date Format.
Function:
[ 0 - 0 ]
Sets the date and time when DST/
summer time ends. The date is
programmed in the format selected
in parameter 0-71 Date Format.
Function:
Enables or disables the clock
warning when the clock has not
been set, or has been reset due to
a power-down and no back-up is
installed. If VLT
MCB 109 is installed, [1] Enabled is
default.
Disabled
Enabled
] and [
].
Function:
Set for each weekday if it is a
working day or a non-working day.
First element of the array is
Monday. The working days are used
for timed actions.
No
Yes
3
®
Analog I/O Option
47
3